Source localization comparison and combination of OPM-MEG and fMRI to detect sensorimotor cortex responses
Computer Methods and Programs in Biomedicine · 2024-09 · 254 · 108292
DOI: 10.1016/j.cmpb.2024.108292 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Computer Methods and Programs in Biomedicine, 2024-09. Verfasst von Nan An und 11 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, …. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Magnetoencephalography, Sensorimotor Cortex. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 46 Literaturangaben. Gefördert von: China Postdoctoral Science Foundation.
Abstract (Originalsprache)
BACKGROUND AND OBJECTIVES: The exploration of various neuroimaging techniques have become focal points within the field of neuroscience research. Magnetoencephalography based on optically pumped magnetometers (OPM-MEG) has shown significant potential to be the next generation of functional neuroimaging with the advantages of high signal intensity and flexible sensor arrangement. In this study, we constructed a 31-channel OPM-MEG system and performed a preliminary comparison of the temporal and spatial relationship between magnetic responses measured by OPM-MEG and blood-oxygen-level-dependent signals detected by functional magnetic resonance imaging (fMRI) during a grasping task. METHODS: For OPM-MEG, the β-band (15-30 Hz) oscillatory activities can be reliably detected across multiple subjects and multiple session runs. To effectively localize the inhibitory oscillatory activities, a source power-spectrum ratio-based imaging method was proposed. This approach was compared with conventional source imaging methods, such as minimum norm-type and beamformer methods, and was applied in OPM-MEG source analysis. Subsequently, the spatial and temporal responses at the source-level between OPM-MEG and fMRI were analyzed. RESULTS: The effectiveness of the proposed method was confirmed through simulations compared to benchmark methods. Our demonstration revealed an average spatial separation of 10.57 ± 4.41 mm between the localization results of OPM-MEG and fMRI across four subjects. Furthermore, the fMRI-constrained OPM-MEG localization results indicated a more focused imaging extent. CONCLUSIONS: Taken together, the performance exhibited by OPM-MEG positions it as a potential instrument for functional surgery assessment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, 100191, China; Hangzhou Institute of Extr…
- Shandong Key Laboratory: Magnetic Field-free Medicine & Functional Imaging, Qilu hospital of Shandong University, Jinan, 250014, China.
Förderung
- China Postdoctoral Science Foundation
Zitieren
APA
An, N., Gao, Z., Li, W., Cao, F., Wang, W., Xu, W., Wang, C., Xiang, M., Gao, Y., Wang, D., Yu, D., & Ning, X. (2024). Source localization comparison and combination of OPM-MEG and fMRI to detect sensorimotor cortex responses. Computer Methods and Programs in Biomedicine, 254, 108292. https://doi.org/10.1016/j.cmpb.2024.108292
Vancouver
An N, Gao Z, Li W, Cao F, Wang W, Xu W, et al. Source localization comparison and combination of OPM-MEG and fMRI to detect sensorimotor cortex responses. Computer Methods and Programs in Biomedicine. 2024;254:108292. doi:10.1016/j.cmpb.2024.108292
BibTeX
@article{An2024,
author = {An, Nan and Gao, Zhenfeng and Li, Wen and Cao, Fuzhi and Wang, Wenli and Xu, Weinan and Wang, Chunhui and Xiang, Min and Gao, Yang and Wang, Dawei and Yu, Dexin and Ning, Xiaolin},
title = {Source localization comparison and combination of OPM-MEG and fMRI to detect sensorimotor cortex responses},
journal = {Computer Methods and Programs in Biomedicine},
year = {2024},
volume = {254},
pages = {108292},
doi = {10.1016/j.cmpb.2024.108292}
}
EUVIMED