EUVIMEDEUVIMED entdecken
VergleichsstudieBeobachtungsstudieOpen Access

Automated Office Blood Pressure Measurements in Waiting Room or Isolated Room for Diagnosis and Phenotyping of Hypertension

Marisol Sánchez Bacaicoa, Sergio Rico iD, Alejandra Gullón iD, Jacinto Fernandez Pardo iD, Juan Villa iD, Eva Nadiejda iD, Roberto Robles, Jose M Del Aguila, Pedro Cunha iD, Valentina Vassilenko iD, Enrique Rodilla iD, Juan F Sánchez Muñoz-Torrero

Journal of the American Heart Association · 21.10.2025 · 14 (20)

DOI: 10.1161/jaha.124.038011 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of the American Heart Association, erschienen am 21.10.2025. Verfasst von Marisol Sánchez Bacaicoa und 11 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology Department Hospital Regional de Málaga Spain. Hauptthemen laut MEDLINE: Blood Pressure, Blood Pressure Determination, Blood Pressure Monitoring, Ambulatory, Hypertension. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Automatic office blood pressure measurement (AOBPM) in the waiting room could improve the performance of diagnosing hypertension without requiring an isolated room to carry out exploration.

Methods

In a cross‐sectional study, we compared the performance to diagnose and phenotyping hypertension by 3 methods of blood pressure measurements, standard office blood pressure, unattended AOBPM in an isolated room or in an office waiting room AOBPM, compared with daytime ambulatory blood pressure measurement (daytime ambulatory blood pressure monitoring) from a 24‐hour ambulatory blood pressure monitoring as a reference. The cutoff values for hypertension and validation for waiting room or isolated room AOBPM were performed by receiver operating characteristic curves and Bland–Altman plots compared with daytime ambulatory blood pressure monitoring.

Results

Out of the 548 participants recruited, 349 (64%) had hypertension, while 199 (36%) were being studied for a diagnosis of hypertension. Waiting room AOBPM and unattended AOBPM stratified hypertension status in a comparable way (n=398; 73% [95% CI, 69%–76%; and n=417; 75% [95% CI, 72%–79%] participants, respectively), and both methods stratified better hypertension status than standard office blood pressure measurement did (n=338; 62% [95% CI, 57%–65%]). Overall, the diagnostic accuracy for white coat syndrome was better for waiting room AOBPM, while for masked hypertension it was by unattended AOBPM (80% [95% CI, 77%–83%] versus 87% [95% CI, 83%–89%] and 88% 95% CI, 85%–90%] versus 73% [95% CI, 69%–76%], respectively).

Conclusions

To assess hypertension status, waiting room AOBPM is equivalent to unattended AOBPM in an isolated room and both better than standard office blood pressure measurement. The detection of hypertension phenotypes differs depending on the site of the measurement, waiting room or isolated room. Registration URL: https://clinicaltrials.gov ; unique identifier: NCT06198855.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood PressureBlood Pressure DeterminationBlood Pressure Monitoring, AmbulatoryHypertensionOffice VisitsAdultAgedFemaleHumansMaleMiddle AgedCross-Sectional StudiesPhenotypePredictive Value of TestsReproducibility of ResultsWhite Coat Hypertension

Stichwörter der Autor:innen

classificationdiagnosishypertensionmasked hypertensionwhite coat hypertension

Autor:innen und Institutionen

  • Cardiology Department Hospital Regional de Málaga Spain.
  • Nursing Department Universidad de Extremadura Spain.
  • Department of Medicine and Hypertension Unit Hospital de la Princesa Madrid Spain.
  • Internal Medicine Department Hospital General Universitario Reina Sofía Murcia Spain.
  • Department of Nephrology Hospital Universitario de Badajoz Spain.
  • Department of Internal Medicine Hospital Infanta Elena Huelva Spain.

ORCID-Profile: Sergio Rico, Alejandra Gullón, Jacinto Fernandez Pardo, Juan Villa, Eva Nadiejda, Pedro Cunha, Valentina Vassilenko, Enrique Rodilla

Zitieren

APA

Sánchez Bacaicoa, M., Rico, S., Gullón, A., Fernandez Pardo, J., Villa, J., Nadiejda, E., Robles, R., Del Aguila, J. M., Cunha, P., Vassilenko, V., Rodilla, E., & Sánchez Muñoz-Torrero, J. F. (2025). Automated Office Blood Pressure Measurements in Waiting Room or Isolated Room for Diagnosis and Phenotyping of Hypertension. Journal of the American Heart Association, 14(20). https://doi.org/10.1161/jaha.124.038011

Vancouver

Sánchez Bacaicoa M, Rico S, Gullón A, Fernandez Pardo J, Villa J, Nadiejda E, et al. Automated Office Blood Pressure Measurements in Waiting Room or Isolated Room for Diagnosis and Phenotyping of Hypertension. Journal of the American Heart Association. 2025;14(20). doi:10.1161/jaha.124.038011

BibTeX
@article{SnchezBacaicoa2025,
  author = {Sánchez Bacaicoa, Marisol and Rico, Sergio and Gullón, Alejandra and Fernandez Pardo, Jacinto and Villa, Juan and Nadiejda, Eva and Robles, Roberto and Del Aguila, Jose M and Cunha, Pedro and Vassilenko, Valentina and Rodilla, Enrique and Sánchez Muñoz-Torrero, Juan F},
  title = {Automated Office Blood Pressure Measurements in Waiting Room or Isolated Room for Diagnosis and Phenotyping of Hypertension},
  journal = {Journal of the American Heart Association},
  year = {2025},
  volume = {14},
  number = {20},
  doi = {10.1161/jaha.124.038011}
}
Kostenlos starten →