Randomisierte kontrollierte Studie

Association of Anxiety with Discrepancies Between Unattended and Attended Office Blood Pressure Measurement

Marek Stopa, Katarzyna Zięba, Anna Tofilska, Barbara Bętkowska-Korpała, Grzegorz Bilo, Marek Rajzer, Agnieszka Olszanecka

American Journal of Hypertension · 2025

DOI: 10.1093/ajh/hpaf075 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift American Journal of Hypertension, 2025. Verfasst von Marek Stopa und 6 weiteren Autor:innen. Beteiligte Einrichtung: First Department of Cardiology and Interventional Electrocardiology and Hypertension, Jagiellonian University Medical College, Krakow, Poland. Hauptthemen laut MEDLINE: Anxiety, Blood Pressure Determination, Hypertension, Blood Pressure. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND Precision of blood pressure (BP) measurements is crucial in hypertension care. Conventional office measurements (OBP) are susceptible to confounding factors, including the white coat effect. An emerging alternative is unattended automated office BP measurement (UAOBP). UAOBP values are typically lower than OBP, but factors responsible for this phenomenon remain poorly understood. The study aimed to analyze factors affecting discrepancies between these methods. METHODS Two hundred and nineteen hypertensive patients completed the State-Trait Anxiety Inventory questionnaire, assessing anxiety levels. Subsequently, BP measurements were performed using two methodologies in a randomized sequence: UAOBP: After a 5-minute rest in the examination room, BP was automatically measured three times at 1-minute intervals. OBP: Following a 5-minute rest, a physician performed three automated oscillometric measurements at 1-minute intervals. RESULTS The BP values obtained through UAOBP were significantly lower than those in OBP: mean (SD) 124.7 (14.4) vs. 128.2 (14.2) mmHg, P < 0.001 for systolic, and 73.3 (10.2) vs. 75.2 (10.6) mmHg, P < 0.001 for diastolic. In the multiple regression analysis, the only factors significantly affecting the differences in systolic BP measurements were trait anxiety level (β = 0.22; P = 0.02) and the order in which the measurements were taken (β = 3.5; P = 0.01). Diastolic BP differences were only predicted by the order of measurement (β = 2.8; P < 0.001). CONCLUSIONS UAOBP appears particularly efficient in mitigating the white coat effect in patients with high levels of anxiety. Further research is needed to investigate whether this may improve the assessment of BP-related risk in such patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AnxietyBlood Pressure DeterminationHypertensionBlood PressureWhite Coat HypertensionOffice VisitsHumansFemaleMaleMiddle AgedAgedAdultSurveys and Questionnaires

Stichwörter der Autor:innen

anxiety levelarterial hypertensionblood pressure measurementunattended automated office blood pressurewhite coat effect

Autor:innen und Institutionen

  • First Department of Cardiology and Interventional Electrocardiology and Hypertension, Jagiellonian University Medical College, Krakow, Poland.
  • Doctoral School of Medical and Health Sciences, Jagiellonian University Medical College, Krakow, Poland.
  • Students Scientific Group, First Department of Cardiology and Interventional Electrocardiology and Hypertension, Jagiellonian University Medical College, Krakow, Poland.
  • Department of Psychiatry, Institute of Medical Psychology, Jagiellonian University Medical College, Krakow, Poland.
  • Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy.
  • Department of Medicine and Surgery, University of Milano-Bicocca, Milan, Italy.

Zitieren

APA

Stopa, M., Zięba, K., Tofilska, A., Bętkowska-Korpała, B., Bilo, G., Rajzer, M., & Olszanecka, A. (2025). Association of Anxiety with Discrepancies Between Unattended and Attended Office Blood Pressure Measurement. American Journal of Hypertension. https://doi.org/10.1093/ajh/hpaf075

Vancouver

Stopa M, Zięba K, Tofilska A, Bętkowska-Korpała B, Bilo G, Rajzer M, et al. Association of Anxiety with Discrepancies Between Unattended and Attended Office Blood Pressure Measurement. American Journal of Hypertension. 2025. doi:10.1093/ajh/hpaf075

BibTeX
@article{Stopa2025,
  author = {Stopa, Marek and Zięba, Katarzyna and Tofilska, Anna and Bętkowska-Korpała, Barbara and Bilo, Grzegorz and Rajzer, Marek and Olszanecka, Agnieszka},
  title = {Association of Anxiety with Discrepancies Between Unattended and Attended Office Blood Pressure Measurement},
  journal = {American Journal of Hypertension},
  year = {2025},
  doi = {10.1093/ajh/hpaf075}
}
Kostenlos starten →