EUVIMEDEUVIMED entdecken
VergleichsstudieMultizentrische StudieOpen Access · CC BY-NC-ND 4.0

Patient Preferences for Features Associated With Leadless Versus Conventional Transvenous Cardiac Pacemakers

Shelby D Reed iD, Jui-Chen Yang iD, Matthew J Wallace, Jessie Sutphin iD, F Reed Johnson iD, Semra Ozdemir iD, Stephanie M Delgado iD, Scott Goates, Nicole Harbert, Monica Lo, Bharath Rajagopalan iD, James E Ip iD und 1 weitere

Circulation: Cardiovascular Quality and Outcomes · 2024

DOI: 10.1161/circoutcomes.124.011168 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Circulation: Cardiovascular Quality and Outcomes, 2024. Verfasst von Shelby D Reed und 12 weiteren Autor:innen. Beteiligte Einrichtung: Duke Clinical Research Institute (S.D.R., J.-C.Y., M.J.W., J.S., F.R.J., S.O., S.M.A.-K.), Duke University School of Medicine, Durham, NC. Hauptthemen laut MEDLINE: Pacemaker, Artificial, Patient Preference, Equipment Design, Cardiac Pacing, Artificial. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Abbott Medical.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Regulatory approval of the first dual-chamber leadless pacemaker system provides patients an alternative to conventional transvenous pacemakers. The study objective was to quantify the preferences of patients for pacemaker features. METHODS: Patients with a de novo (ie, initial) pacemaker indication were recruited from 7 US sites to complete a Web-based discrete-choice experiment survey between May 11, 2022, and May 24, 2023. Patients chose between pairs of experimentally designed, hypothetical pacemakers that varied according to type (removable leadless, nonremovable leadless, or conventional transvenous); battery life (5, 8, 12, or 15 years); time since regulatory approval (2 or 10 years); discomfort for 6 months (none or discomfort); and complication risk and infection risk (1%, 5%, or 10%/20% for each). Patients’ choice data were analyzed using random-parameter logit models and latent-class analysis. RESULTS: Among 117 participants, the mean (SD) age was 67.3 (14.6) years, 94% were white, and 42% were female. On average, patients’ survey responses revealed a preference for removable leadless pacemakers (β, 0.340; SE, 0.096) over both nonremovable leadless pacemakers (β, −0.310; SE, 0.131; P =0.001) and conventional transvenous pacemakers (β, −0.030; SE, 0.119; P =0.031). However, latent-class analysis revealed 2 distinct preference classes. One class preferred leadless pacemakers (50.5%), and the other class preferred conventional transvenous pacemakers (49.5%). The conventional pacemaker class prioritized pacemakers with 10 rather than 2 years since regulatory approval ( P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pacemaker, ArtificialPatient PreferenceEquipment DesignCardiac Pacing, ArtificialChoice BehaviorHumansAgedFemaleMaleMiddle AgedAged, 80 and overUnited StatesTime FactorsRisk FactorsArrhythmias, CardiacElectric Power SuppliesRisk AssessmentHealth Care SurveysTreatment Outcome

Stichwörter der Autor:innen

logistic modelspacemaker, artificialpatient preferencepatient-centered caresurvey

Autor:innen und Institutionen

  • Duke Clinical Research Institute (S.D.R., J.-C.Y., M.J.W., J.S., F.R.J., S.O., S.M.A.-K.), Duke University School of Medicine, Durham, NC.
  • Department of Population Health Sciences (S.D.R., F.R.J., S.O.), Duke University School of Medicine, Durham, NC.
  • Signature Programme in Health Services and Systems Research, Duke-NUS Medical School, Singapore (S.O.).
  • Abbott Medical, Sylmar, CA (S.M.D., S.G., N.H.).
  • Arkansas Heart Hospital, Little Rock (M.L.).
  • Prairie Education and Research Cooperative, Springfield, IL (B.R.).

ORCID-Profile: Shelby D Reed, Jui-Chen Yang, Jessie Sutphin, F Reed Johnson, Semra Ozdemir, Stephanie M Delgado, Bharath Rajagopalan, James E Ip, Sana M Al-Khatib

Förderung

  • Abbott Medical

Zitieren

APA

Reed, S. D., Yang, J. C., Wallace, M. J., Sutphin, J., Johnson, F. R., Ozdemir, S., Delgado, S. M., Goates, S., Harbert, N., Lo, M., Rajagopalan, B., Ip, J. E., & Al-Khatib, S. M. (2024). Patient Preferences for Features Associated With Leadless Versus Conventional Transvenous Cardiac Pacemakers. Circulation: Cardiovascular Quality and Outcomes. https://doi.org/10.1161/circoutcomes.124.011168

Vancouver

Reed SD, Yang JC, Wallace MJ, Sutphin J, Johnson FR, Ozdemir S, et al. Patient Preferences for Features Associated With Leadless Versus Conventional Transvenous Cardiac Pacemakers. Circulation: Cardiovascular Quality and Outcomes. 2024. doi:10.1161/circoutcomes.124.011168

BibTeX
@article{Reed2024,
  author = {Reed, Shelby D and Yang, Jui-Chen and Wallace, Matthew J and Sutphin, Jessie and Johnson, F Reed and Ozdemir, Semra and Delgado, Stephanie M and Goates, Scott and Harbert, Nicole and Lo, Monica and Rajagopalan, Bharath and Ip, James E and Al-Khatib, Sana M},
  title = {Patient Preferences for Features Associated With Leadless Versus Conventional Transvenous Cardiac Pacemakers},
  journal = {Circulation: Cardiovascular Quality and Outcomes},
  year = {2024},
  doi = {10.1161/circoutcomes.124.011168}
}
Kostenlos starten →