Abstract 6807: Prognostic Role of Wideband Quantitative Stress Perfusion CMR in Patients with Cardiac Implantable Electronic Devices
Circulation · 02.11.2026 · 154 (Suppl_1)
DOI: 10.1161/circ.154.suppl_1.6807 ↗Kurz gefasst
Fachartikel in der Zeitschrift Circulation, erschienen am 02.11.2026. Verfasst von Amir Hossein Behnoush und 12 weiteren Autor:innen.
Abstract (Originalsprache)
Background
The prognostic value of stress perfusion cardiac magnetic resonance (CMR) is well established, with growing evidence supporting quantitative perfusion. While patients with cardiac implantable electronic devices (CIEDs) now routinely undergo non-stress CMR using established safety protocols, prognostic data for stress CMR in this population remain limited. Recent wideband sequences reduce device-related artifacts and enable diagnostic stress CMR in CIED patients. Hypothesis: We aimed to evaluate the prognostic value of quantitative stress CMR metrics in patients with CIED.
Methods
Patients with CIED who underwent CMR with rest and stress perfusion imaging between 2020 and 2025 were included. Quantitative metrics derived from CMR perfusion signal intensity-time curves were rest and stress myocardial blood flow (MBF), myocardial perfusion reserve (MPR), rest and stress pulmonary transit time (PTT). Patients were followed for at least one year for major adverse cardiovascular events (MACE), defined as myocardial infarction, heart failure hospitalization, appropriate implantable cardioverter-defibrillator (ICD) therapy, cardiac death, coronary revascularization, or heart transplantation. The prognostic value of stress MBF, MPR, rest and stress PTT was assessed using Cox proportional hazards models.
Results
Of the 89 CIED patients (64.9±14.7 years, 63% male), 30 had pacemakers, 43 had ICD, 12 had CRT-D, and 4 had CRT-P. The mean LVEF was 43 ± 15%, and 62 patients had late gadolinium enhancement (LGE). Median stress MBF was 1.92 ml/min/g [1.44-2.32], median rest MBF was 0.86 ml/min/g [0.74-1.08], and median MPR was 2.04 [1.56-2.55]. Median PTT was 8.89s [6.97-11.03] at rest and 7.85s [6.29-10] at stress. During a median follow-up of 26 months [15-38], 27 patients (30%) experienced MACE. Each 0.5 mL/min/g decrease in stress MBF was associated with a 46% higher risk of MACE (HR 1.46 [95%CI 1.06-1.99], P=0.019), while lower MPR was also associated with increased MACE (HR per 0.5 decrease 1.43 [1.01-2.01], P=0.043). Each 1-second increase in rest PTT (HR 1.173 [1.044-1.318], P=0.007) and stress PTT (HR 1.134 [1.037-1.24], P=0.006) was associated with higher MACE. Kaplan-Meier analyses showed significant differences in MACE-free survival by stress MBF, MPR, and rest PTT. When patients were stratified into four groups based on LGE presence/absence and high/low perfusion metrics, significant differences in event rates were observed across groups (all log-rank P
Zitieren
APA
Behnoush, A. H., Jimenez, M. D., Fan, L., Urban, J., Starrett, L., Topel, C., Gill, N., Hong, K., Collins, J. D., Patel, A., knight, B., Kim, D., & Lee, D. C. (2026). Abstract 6807: Prognostic Role of Wideband Quantitative Stress Perfusion CMR in Patients with Cardiac Implantable Electronic Devices. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.6807
Vancouver
Behnoush AH, Jimenez MD, Fan L, Urban J, Starrett L, Topel C, et al. Abstract 6807: Prognostic Role of Wideband Quantitative Stress Perfusion CMR in Patients with Cardiac Implantable Electronic Devices. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.6807
BibTeX
@article{Behnoush2026,
author = {Behnoush, Amir Hossein and Jimenez, Maria Davo and Fan, Lexiaozi and Urban, Jacqueline and Starrett, Lane and Topel, Cagdas and Gill, Nathan and Hong, KyungPyo and Collins, Jeremy D and Patel, Amit and knight, bradley and Kim, Daniel and Lee, Daniel C},
title = {Abstract 6807: Prognostic Role of Wideband Quantitative Stress Perfusion CMR in Patients with Cardiac Implantable Electronic Devices},
journal = {Circulation},
year = {2026},
volume = {154},
number = {Suppl_1},
doi = {10.1161/circ.154.suppl_1.6807}
}
EUVIMED