Wideband Late Gadolinium Enhancement CMR in Patients With Cardiac Implantable Electronic Devices: A Systematic Review and Outcome-Specific Quantitative Synthesis
SN Comprehensive Clinical Medicine · 12.11.2026 · 8 (1)
DOI: 10.1007/s42399-026-02862-2 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift SN Comprehensive Clinical Medicine, online erschienen am 12.11.2026. Verfasst von Abdulrhman H. M. Muhaisen und 1 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben.
Abstract (Originalsprache)
Cardiac implantable electronic devices (CIEDs) can cause substantial off-resonance artifact on late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR). We systematically evaluated wideband LGE for diagnostic interpretability, artifact suppression, scar assessment, electroanatomical mapping (EAM) concordance, clinical impact, and safety. PubMed/MEDLINE, Scopus, and Web of Science were searched through 3 August 2026. Human studies evaluating true wideband LGE in patients with CIEDs were included; overlapping cohorts were de-duplicated by outcome. Paired artifact-related endpoints were analyzed separately using exact discordant-pair methods, and myocardial LGE prevalence was synthesized with a random-effects logit model. The review was registered in PROSPERO (CRD420261474408). Eighteen reports were included. In Stevens et al., diagnostic interpretability improved from 2/18 (11.1%) with conventional LGE to 17/18 (94.4%) with wideband LGE, an absolute increase of 83.3% points; all 15 discordant pairs favored wideband. In Runge et al., artifact-free examinations increased from 18/50 (36.0%) to 38/50 (76.0%), an absolute increase of 40.0% points; all 20 discordant pairs favored wideband. Exploratory pooled myocardial LGE prevalence across four independent cohorts was 75.2% (95% CI 63.4%–84.1%; I²=18.1%). No serious scan-related patient adverse events were reported among 525 deduplicated CIED patients (0%; exact 95% CI 0%–0.70%); however, nonserious events and device-specific effects occurred, including permanent S-ICD beeper-volume loss in 12/23 patients in one cohort. Two small paired studies showed large artifact-related improvements favoring wideband LGE, while evidence regarding downstream clinical impact and safety remains predominantly observational. Larger prospective multicenter studies with standardized outcome definitions and dedicated patient- and device-safety reporting are needed.
Zitieren
APA
Muhaisen, A. H. M., & Rawashdeh, B. M. M. (2026). Wideband Late Gadolinium Enhancement CMR in Patients With Cardiac Implantable Electronic Devices: A Systematic Review and Outcome-Specific Quantitative Synthesis. SN Comprehensive Clinical Medicine, 8(1). https://doi.org/10.1007/s42399-026-02862-2
Vancouver
Muhaisen AHM, Rawashdeh BMM. Wideband Late Gadolinium Enhancement CMR in Patients With Cardiac Implantable Electronic Devices: A Systematic Review and Outcome-Specific Quantitative Synthesis. SN Comprehensive Clinical Medicine. 2026;8(1). doi:10.1007/s42399-026-02862-2
BibTeX
@article{Muhaisen2026,
author = {Muhaisen, Abdulrhman H. M. and Rawashdeh, Balqees Mohammed M.},
title = {Wideband Late Gadolinium Enhancement CMR in Patients With Cardiac Implantable Electronic Devices: A Systematic Review and Outcome-Specific Quantitative Synthesis},
journal = {SN Comprehensive Clinical Medicine},
year = {2026},
volume = {8},
number = {1},
doi = {10.1007/s42399-026-02862-2}
}
EUVIMED