EUVIMEDEUVIMED entdecken
Open Access

Skin Thickness Over Cardiac Implantable Electronic Devices: Prognostic Impact and Longitudinal Changes

Shogo Yonehara, Mitsuru Takami iD, Atsusuke Yatomi, Kimitake Imamura, Kunihiko Kiuchi, Hidehiro Iwai, Mitsuhiko Shoda, Atsushi Murakami, Hiroyuki Asada, Takahiro Kunigita, Mari Yamamoto, Ryosuke Takahashi und 5 weitere

Pacing and Clinical Electrophysiology · 2026-08 · 49 (8) · 1028-1035

DOI: 10.1111/pace.70210 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 17.03.2026. Verfasst von Shogo Yonehara und 16 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Pacemaker, Artificial, Skin. Die Arbeit nennt 12 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Skin thinning over cardiac implantable electronic devices (CIEDs) is frequently observed; however, its clinical implications and temporal progression remain unclear. This study aimed to investigate the clinical significance of skin thickness over CIEDs by examining its association with adverse outcomes, including all‐cause mortality and device‐related infections, and evaluating its temporal changes and associated clinical factors.

Methods

This study included 96 patients who underwent ultrasonographic measurement of skin thickness over CIEDs between June 2020 and June 2021. Adverse outcomes were monitored through August 2023. Of those, 34 patients had follow‐up ultrasonography to assess temporal changes in skin thickness.

Results

Among 34 patients with repeated measurements, skin thickness significantly declined over a median of 42 (IQR: 41–44) months ( p = 0.001), and thinning was correlated with changes in hemoglobin levels ( r = 0.392, p = 0.024). During a median follow‐up of 32 (IQR: 11–34) months, patients with skin thickness ≤ 3.3 mm (thin group) had significantly higher all‐cause mortality than those with a thickness > 3.3 mm (normal group) (log‐rank p < 0.001). In multivariable Cox regression analysis, skin thickness ≤ 3.3 mm remained an independent predictor of mortality (HR 2.42; 95% CI, 1.01–5.80; p = 0.046). Device‐related infections were more frequent in the thin group (8%) than in the normal group (2%), but the difference was not statistically significant.

Conclusions

Skin thickness over CIEDs progressively declined over time and was significantly correlated with hemoglobin levels. In addition, skin thickness ≤ 3.3 mm was independently associated with increased all‐cause mortality.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantablePacemaker, ArtificialSkinHumansFemaleMalePrognosisUltrasonographyAgedProsthesis-Related InfectionsLongitudinal Studies

Stichwörter der Autor:innen

anemiacardiac implantable electronic devicedevice infectionmortalityskin thicknessultrasonography

Autor:innen und Institutionen

  • Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan.
  • Department of Cardiology, Kobe Red Cross Hospital, Kobe, Japan.
  • Section of Arrhythmia, Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan.
  • Department of Medical Device Engineering, Kobe University Graduate School of Medicine, Kobe, Japan.
  • Center For Advanced Medical Engineering Research and Development, Kobe University, Kobe, Japan.

ORCID-Profile: Mitsuru Takami

Zitieren

APA

Yonehara, S., Takami, M., Yatomi, A., Imamura, K., Kiuchi, K., Iwai, H., Shoda, M., Murakami, A., Asada, H., Kunigita, T., Yamamoto, M., Takahashi, R., Suehiro, W., Tsuboi, T., Nakano, T., Fukuzawa, K., & Otake, H. (2026). Skin Thickness Over Cardiac Implantable Electronic Devices: Prognostic Impact and Longitudinal Changes. Pacing and Clinical Electrophysiology, 49(8), 1028-1035. https://doi.org/10.1111/pace.70210

Vancouver

Yonehara S, Takami M, Yatomi A, Imamura K, Kiuchi K, Iwai H, et al. Skin Thickness Over Cardiac Implantable Electronic Devices: Prognostic Impact and Longitudinal Changes. Pacing and Clinical Electrophysiology. 2026;49(8):1028-1035. doi:10.1111/pace.70210

BibTeX
@article{Yonehara2026,
  author = {Yonehara, Shogo and Takami, Mitsuru and Yatomi, Atsusuke and Imamura, Kimitake and Kiuchi, Kunihiko and Iwai, Hidehiro and Shoda, Mitsuhiko and Murakami, Atsushi and Asada, Hiroyuki and Kunigita, Takahiro and Yamamoto, Mari and Takahashi, Ryosuke and Suehiro, Wako and Tsuboi, Takafumi and Nakano, Takahito and Fukuzawa, Koji and Otake, Hiromasa},
  title = {Skin Thickness Over Cardiac Implantable Electronic Devices: Prognostic Impact and Longitudinal Changes},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  volume = {49},
  number = {8},
  pages = {1028--1035},
  doi = {10.1111/pace.70210}
}
Kostenlos starten →