Implant Position Accuracy of a Dual-Function Bite Holder for Single-Visit Registration of Complete-Arch Implants and Maxillomandibular Relationship: An In Vitro Study
The International Journal of Oral & Maxillofacial Implants · 2026-11 · 1-27
DOI: 10.11607/jomi.11903 ↗At a glance
Journal article in The International Journal of Oral & Maxillofacial Implants, 2026-11. Written by Ra'fat I Farah and 3 co-authors.
Abstract (original language)
PURPOSE: To evaluate the accuracy of implant spatial positions obtained through a proposed bite holder digital substitution workflow compared to conventional direct scan body scanning. MATERIAL AND METHODS: A mandibular model with four implant analogs was fabricated and digitized with a desktop scanner to establish the reference standard. Two protocols were compared: direct scan body scanning (n=10) and bite holder scanning with digital substitution (n=10), both performed with an intraoral scanner. In the substitution method, bite holders were virtually replaced with scan bodies using a superimposition workflow in computer-aided design (CAD) software. Three-dimensional RMS deviation, linear deviation, and angular deviation were quantified using metrology software. Hotelling's T² test compared overall accuracy between methods (α=0.05), followed by protected univariate tests with Bonferroni correction. An equivalence analysis was performed using the two one-sided tests procedure with clinical margins of ±100 μm and ±0.4°. RESULTS: Direct scanning achieved RMS, linear, and angular deviations of 56.3±14.5 μm, 67.5±15.7 μm, and 0.37±0.06°, respectively. The substitution method demonstrated 85.2±18.0 μm, 96.6±15.0 μm, and 0.63±0.07°, respectively. Direct scanning showed statistically superior accuracy (P
Subjects
Author keywords
Cite
APA
Farah, R. I., Alwably, A., Alfurayhi, A., & Alfawzan, A. (2026). Implant Position Accuracy of a Dual-Function Bite Holder for Single-Visit Registration of Complete-Arch Implants and Maxillomandibular Relationship: An In Vitro Study. The International Journal of Oral & Maxillofacial Implants, 1-27. https://doi.org/10.11607/jomi.11903
Vancouver
Farah RI, Alwably A, Alfurayhi A, Alfawzan A. Implant Position Accuracy of a Dual-Function Bite Holder for Single-Visit Registration of Complete-Arch Implants and Maxillomandibular Relationship: An In Vitro Study. The International Journal of Oral & Maxillofacial Implants. 2026:1-27. doi:10.11607/jomi.11903
BibTeX
@article{Farah2026,
author = {Farah, Ra'fat I and Alwably, Abdulmajeed and Alfurayhi, Abdulaziz and Alfawzan, Asim},
title = {Implant Position Accuracy of a Dual-Function Bite Holder for Single-Visit Registration of Complete-Arch Implants and Maxillomandibular Relationship: An In Vitro Study},
journal = {The International Journal of Oral & Maxillofacial Implants},
year = {2026},
pages = {1--27},
doi = {10.11607/jomi.11903}
}