Clinical Evaluation of Short and Standard-Length Implants in Posterior Regions of the Partially Edentulous Maxilla and Mandible – A Prospective Comparative Study

Frank Peter Strietzel, Henrik Dommisch

The International Journal of Oral & Maxillofacial Implants · 2025

DOI: 10.11607/jomi.11559 ↗

At a glance

Vergleichsstudie in The International Journal of Oral & Maxillofacial Implants, 2025. Written by Frank Peter Strietzel and 1 co-authors. Major MEDLINE topics: Dental Implants, Dental Prosthesis Design, Jaw, Edentulous, Partially, Maxilla.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

PURPOSE: To compare clinical outcomes of short (6 and 8 mm) and standard-length (11 and 13 mm) implants in posterior sites. MATERIALS AND METHODS: In this prospective observational study, implant survival and success rates, soft tissue conditions, and marginal bone level change (MBLC) were observed over a period up to 36 months. Short and standardlength OsseoSpeed Astra Tech implants were used to replace two or three missing teeth. A total of 38 patients-with 42 standard-length implants and 64 short implants-were available for follow-up. Data regarding the patients' medical history and clinical and radiographic parameters were analyzed. No implant loss or mobility was recorded throughout the observation period. RESULTS: Regarding an MBLC of ≥ 2 mm, no significant difference in the success rates of short (76.9%) and standard-length (76.2%) implants was found. Considering MBLC in each group, success rates of short (88.7%) and standard-length (100%) implants differed significantly (log-rank test, P = .028). Compromised medical history, implant site location (maxilla or mandible), bone quality, type of prosthetic restoration (single nonsplinted or splinted crowns or fixed partial dentures), and keratinized mucosa width ≥ 2 mm were not associated with MBLC. Premature cover screw exposure and MBLC ≥ 2 mm were significantly associated within short implants (P = .045) but not standard-length implants (P = .853). Short implants in smokers were at a higher risk of MBLC > 3/10 of implant length compared to nonsmokers (P = .022). CONCLUSIONS: Short and standard-length implants revealed comparable survival and success rates regarding MBLC ≥ 2 mm but differed significantly considering MBLC > 3/10 of the endosseous implant length. Short implants are more prone to MBLC compared to standard-length implants, especially in smokers or when premature cover screw exposures occur.

Subjects

MeSH terms (MEDLINE)

Dental ImplantsDental Prosthesis DesignJaw, Edentulous, PartiallyMaxillaDental Implantation, EndosseousHumansProspective StudiesFemaleMaleMiddle AgedTreatment OutcomeMandibleAgedAdultDental Restoration FailureDental Prosthesis, Implant-Supported

Author keywords

dental implantsmarginal bone level changeshort implantsstandard-length implantssuccess ratesurvival rate

Substances

Dental Implants

Cite

APA

Strietzel, F. P., & Dommisch, H. (2025). Clinical Evaluation of Short and Standard-Length Implants in Posterior Regions of the Partially Edentulous Maxilla and Mandible – A Prospective Comparative Study. The International Journal of Oral & Maxillofacial Implants. https://doi.org/10.11607/jomi.11559

Vancouver

Strietzel FP, Dommisch H. Clinical Evaluation of Short and Standard-Length Implants in Posterior Regions of the Partially Edentulous Maxilla and Mandible – A Prospective Comparative Study. The International Journal of Oral & Maxillofacial Implants. 2025. doi:10.11607/jomi.11559

BibTeX
@article{Strietzel2025,
  author = {Strietzel, Frank Peter and Dommisch, Henrik},
  title = {Clinical Evaluation of Short and Standard-Length Implants in Posterior Regions of the Partially Edentulous Maxilla and Mandible – A Prospective Comparative Study},
  journal = {The International Journal of Oral & Maxillofacial Implants},
  year = {2025},
  doi = {10.11607/jomi.11559}
}
Start for free →