Clinical and radiographic performance of late placed and early loaded dental implants with a conditioned hydrophilic surface in posterior mandible sites: A prospective case series with an 8.5‐ to 9.5‐year follow‐up
Clinical Implant Dentistry and Related Research · 2024
DOI: 10.1111/cid.13333 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Implant Dentistry and Related Research, 2024. Verfasst von Pedro Molinero-Mourelle und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland. Hauptthemen laut MEDLINE: Mandible. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objective
To assess the clinical outcomes by means of implant and prosthetic survival of late placed and early loaded implants with a hydrophilic, moderately rough surface for partially edentulous patients after a follow‐up of 8.5 to 9.5 years. Materials and methods A prospective case series study involving 15 patients with single, late placed and early loaded implants in the posterior mandible was performed. Clinical and radiographical parameters, including biological and technical complications and patient satisfaction, were assessed.
Results
From an initial sample of 15 patients, 12 were included. A total of 16 implants were observed. After a mean follow‐up of 9 years and 7 months (SD ± 3.8 months), implant success and survival rate were 100%. The prosthetic survival rate was 100%, and the prosthetic success rate was 93.8% since a major chipping was observed. No biological complications were observed, and the mean modified plaque index was 0.03 (SD ± 0.09) with a mean probing pocket depth of 2.95 mm (SD ± 0.09). A mean marginal bone level (MBL) of 0.04 mm (SD ± 0.88) and a mean VAS of 9.42 (SD ± 0.90) for patient satisfaction were recorded.
Conclusion
Late placed and early loaded implants with a moderately rough endosseal surface are a reliable option for rehabilitating partially edentulous patients. An implant survival rate of 100% and a prosthodontic success rate of 93.8% were observed. Patient satisfaction scores were high and peri‐implant hard and soft tissues remained healthy. The study findings should be carefully interpreted because of the small sample.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.
- Private Practice, Weinfelden, Switzerland.
- Clinic of Preventive Dentistry, Periodontology and Cariology, and Clinic of General, Special Care and Geriatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland.
ORCID-Profile: Martin Schimmel, Clemens Raabe, Manrique Fonseca
Zitieren
APA
Molinero-Mourelle, P., Schimmel, M., Forrer, F. A., Hicklin, S. P., Raabe, C., Chappuis, V., & Fonseca, M. (2024). Clinical and radiographic performance of late placed and early loaded dental implants with a conditioned hydrophilic surface in posterior mandible sites: A prospective case series with an 8.5‐ to 9.5‐year follow‐up. Clinical Implant Dentistry and Related Research. https://doi.org/10.1111/cid.13333
Vancouver
Molinero-Mourelle P, Schimmel M, Forrer FA, Hicklin SP, Raabe C, Chappuis V, et al. Clinical and radiographic performance of late placed and early loaded dental implants with a conditioned hydrophilic surface in posterior mandible sites: A prospective case series with an 8.5‐ to 9.5‐year follow‐up. Clinical Implant Dentistry and Related Research. 2024. doi:10.1111/cid.13333
BibTeX
@article{MolineroMourelle2024,
author = {Molinero-Mourelle, Pedro and Schimmel, Martin and Forrer, Fiona Alena and Hicklin, Stefan Paul and Raabe, Clemens and Chappuis, Vivianne and Fonseca, Manrique},
title = {Clinical and radiographic performance of late placed and early loaded dental implants with a conditioned hydrophilic surface in posterior mandible sites: A prospective case series with an 8.5‐ to 9.5‐year follow‐up},
journal = {Clinical Implant Dentistry and Related Research},
year = {2024},
doi = {10.1111/cid.13333}
}
EUVIMED