AI-Driven Design of Auxiliary Devices to Improve Intraoral Scanning Accuracy in Complete-Arch Implant Cases
The International Journal of Oral & Maxillofacial Implants · 2025
DOI: 10.11607/jomi.11415 ↗Kurz gefasst
Fachartikel in der Zeitschrift The International Journal of Oral & Maxillofacial Implants, 2025. Verfasst von Yu Pan und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Dental Implants, Deep Learning, Artificial Intelligence.
Abstract (Originalsprache)
PURPOSE: To develop auxiliary devices for intraoral scanning (IOS) of complete-arch implant cases using a deep-learning artificial intelligence (AI) model. MATERIALS AND METHODS: A total of 338 3D-imaging data sets were collected from a dental laboratory. Of these, 300 sets of complete dental arches were used for training, 28 sets were used for validation, and 10 edentulous arches with four to six dental implants were used for testing. Auxiliary devices with landmarks placed in between implants to aid in image stitching were manually designed and used as a control. A multilayer perceptron artificial neural network was employed to predict the positions of the landmarks, with normalized implant coordinates being used for input and landmark coordinates being used for output. The model was validated and evaluated using the test set to assess the fit of the base as well as the surface area of the landmarks. RESULTS: The bounding box loss for the training and validation sets converged to 0.02 and 0.01, respectively, which indicated high precision in landmark position prediction. The objectness loss stabilized at 0.05 for the training set and 0.03 for the validation set, confirming the model's robust detection capability. The root mean square (RMS) of the device base was 0.117 ± 0.053 mm, significantly smaller than the clinical threshold of 0.300 mm (P < .001). The surface area of the AIgenerated device landmarks (762.0 ± 141.7 mm2) was significantly smaller than that of the manually designed control (1,307.1 ± 286.1 mm2, P = .001). CONCLUSIONS: The AI model demonstrated exceptional performance in this study. The base of the AI-generated auxiliary device fit well with the edentulous region, though its landmark teeth were smaller than those in the manually designed control.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Zitieren
APA
Pan, Y., Chen, W., Moy, P., & Pow, E. H. N. (2025). AI-Driven Design of Auxiliary Devices to Improve Intraoral Scanning Accuracy in Complete-Arch Implant Cases. The International Journal of Oral & Maxillofacial Implants. https://doi.org/10.11607/jomi.11415
Vancouver
Pan Y, Chen W, Moy P, Pow EHN. AI-Driven Design of Auxiliary Devices to Improve Intraoral Scanning Accuracy in Complete-Arch Implant Cases. The International Journal of Oral & Maxillofacial Implants. 2025. doi:10.11607/jomi.11415
BibTeX
@article{Pan2025,
author = {Pan, Yu and Chen, Weixuan and Moy, Peter and Pow, Edmond H N},
title = {AI-Driven Design of Auxiliary Devices to Improve Intraoral Scanning Accuracy in Complete-Arch Implant Cases},
journal = {The International Journal of Oral & Maxillofacial Implants},
year = {2025},
doi = {10.11607/jomi.11415}
}
EUVIMED