EUVIMEDEUVIMED entdecken
StudienprotokollOpen Access · CC BY-NC-ND 4.0

Influence of scanning protocol on the accuracy of complete‐arch digital implant scans: An in vitro study

Adam Hamilton iD, William Matthew Negreiros, Shruti Jain, Matthew Finkelman, German O Gallucci iD

Clinical Oral Implants Research · 2024

DOI: 10.1111/clr.14259 ↗

Kurz gefasst

Studienprotokoll in der Zeitschrift Clinical Oral Implants Research, 2024. Verfasst von Adam Hamilton und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Regenerative and Implant Sciences, Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Bost…. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: International Team for Implantology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This in‐vitro study assessed the influence of two intraoral scanning (IOS) protocols on the accuracy (trueness and precision) of digital scans performed in edentulous arches.

Methods

Twenty‐two abutment‐level master casts of edentulous arches with at least four implants were scanned repeatedly five times, each with two different scanning protocols. Protocol A (IOS‐A) consisted of scanning the edentulous arch before inserting the implant scan bodies, followed by their insertion and its subsequent digital acquisition. Protocol B (IOS‐B) consisted of scanning the edentulous arch with the scan bodies inserted from the outset. A reference scan from each edentulous cast was obtained using a laboratory scanner. Trueness and precision were calculated using the spatial fit analysis, cross‐arch distance, and virtual Sheffield test. Statistical analysis was performed using generalized estimating equations (GEEs). Statistical significance was set at α = .05.

Results

In the spatial fit test, the precision of average 3D distances was 45 μm (±23 μm) with protocol IOS‐A and 25 μm (±10 μm) for IOS‐B ( p < .001), and the trueness of average 3D distances was 44 μm (±24 μm) with protocol IOS‐A and 24 μm (±7 μm) for IOS‐B ( p < .001). Cross‐arch distance precision was 59 μm (±53 μm) for IOS‐A and 41 μm (±43 μm) for IOS‐B ( p = .0035), and trueness was 64 μm (±47 μm) for IOS‐A and 50 μm (±40 μm) for IOS‐B ( p = .0021). Virtual Sheffield precision was 286 μm (±198 μm) for IOS‐A and 146 μm (±92 μm) for IOS‐B ( p < .001), and trueness was 228 μm (±171 μm) for IOS‐A and 139 μm (±92 μm) for IOS‐B ( p < .001).

Conclusions

The IOS‐B protocol demonstrated significantly superior accuracy. Placement of scan bodies before scanning the edentulous arch is recommended to improve the accuracy of complete‐arch intraoral scanning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalHumansIn Vitro TechniquesDental ImplantsComputer-Aided DesignJaw, EdentulousModels, DentalDental Arch

Stichwörter der Autor:innen

accuracydental implantsdigital impressiondigital intraoral scanningedentulous

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Division of Regenerative and Implant Sciences, Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA.
  • Division of Oral Restorative and Rehabilitative Sciences, University of Western Australia, Perth, Western Australia, Australia.
  • Department of Public Health and Community Service, Tufts University School of Dental Medicine, Boston, Massachusetts, USA.
  • Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA.

ORCID-Profile: Adam Hamilton, German O Gallucci

Förderung

  • International Team for Implantology

Zitieren

APA

Hamilton, A., Negreiros, W. M., Jain, S., Finkelman, M., & Gallucci, G. O. (2024). Influence of scanning protocol on the accuracy of complete‐arch digital implant scans: An in vitro study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.14259

Vancouver

Hamilton A, Negreiros WM, Jain S, Finkelman M, Gallucci GO. Influence of scanning protocol on the accuracy of complete‐arch digital implant scans: An in vitro study. Clinical Oral Implants Research. 2024. doi:10.1111/clr.14259

BibTeX
@article{Hamilton2024,
  author = {Hamilton, Adam and Negreiros, William Matthew and Jain, Shruti and Finkelman, Matthew and Gallucci, German O},
  title = {Influence of scanning protocol on the accuracy of complete‐arch digital implant scans: An in vitro study},
  journal = {Clinical Oral Implants Research},
  year = {2024},
  doi = {10.1111/clr.14259}
}
Kostenlos starten →