EUVIMEDOpdag EUVIMED
Vergleichsstudie

Comparative Accuracy of Static vs Dynamic Guidance for Dental Implant Placement on Vascularized Bone Flap Reconstruction: A Retrospective Study

Jie Liang, Yifan Kang, Zichao Wang, Yanjun Ge, Xiaofeng Shan, Zhigang Cai

The International Journal of Oral & Maxillofacial Implants · 2025

DOI: 10.11607/jomi.11330 ↗

At a glance

Vergleichsstudie in The International Journal of Oral & Maxillofacial Implants, 2025. Written by Jie Liang and 5 co-authors. Major MEDLINE topics: Surgical Flaps, Dental Implantation, Endosseous, Surgery, Computer-Assisted, Dental Implants.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

PURPOSE: To evaluate and compare the accuracy of dental implant placement on vascularized bone flaps (VBFs) reconstructed for dental arch defects using static computer-assisted implant surgery (s-CAIS) and dynamic computerassisted implant surgery (d-CAIS). MATERIALS AND METHODS: This retrospective study included patients who underwent s-CAIS or d-CAIS implant placement following VBF reconstruction between October 2021 and October 2023. A total of 23 patients were included: 9 patients (33 implants) in the d-CAIS group and 14 patients (41 implants) in the s-CAIS group. Accuracy was assessed by comparing the preoperative design and postoperative results from CBCT. Key parameters-such as angulation deviation, global deviation at the platform and apex, and bidirectional deviations (mesiodistal, buccolingual, and apicocoronal)-were measured and compared between groups. RESULTS: The d-CAIS group demonstrated significantly lower global deviation (P < .01) and apicocoronal deviation at the apex (P < .05) compared to the s-CAIS group. Superior accuracy was also observed in the d-CAIS group for posterior implants, particularly in apicocoronal deviation at both the platform and apex levels (P < .01). Additionally, d-CAIS outperformed s-CAIS for mandibular implants, showing significantly lower buccolingual deviation at both the platform and apex levels (P < .05). For implants on iliac flaps, d-CAIS exhibited lower angulation deviation and global deviation at the platform and apex levels (P < .05). CONCLUSIONS: When placing implants on VBF-reconstructed dental arches, dynamic guidance demonstrated superior precision, particularly in controlling depth and apex deviation.

Subjects

MeSH terms (MEDLINE)

Surgical FlapsDental Implantation, EndosseousSurgery, Computer-AssistedDental ImplantsPlastic Surgery ProceduresHumansRetrospective StudiesFemaleMaleMiddle AgedCone-Beam Computed TomographyBone TransplantationAdultAged

Author keywords

accuracydental implantsdynamic guidanceimplant surgerynavigationstatic guidancesurgical guidevascularized bone flap

Substances

Dental Implants

Cite

APA

Liang, J., Kang, Y., Wang, Z., Ge, Y., Shan, X., & Cai, Z. (2025). Comparative Accuracy of Static vs Dynamic Guidance for Dental Implant Placement on Vascularized Bone Flap Reconstruction: A Retrospective Study. The International Journal of Oral & Maxillofacial Implants. https://doi.org/10.11607/jomi.11330

Vancouver

Liang J, Kang Y, Wang Z, Ge Y, Shan X, Cai Z. Comparative Accuracy of Static vs Dynamic Guidance for Dental Implant Placement on Vascularized Bone Flap Reconstruction: A Retrospective Study. The International Journal of Oral & Maxillofacial Implants. 2025. doi:10.11607/jomi.11330

BibTeX
@article{Liang2025,
  author = {Liang, Jie and Kang, Yifan and Wang, Zichao and Ge, Yanjun and Shan, Xiaofeng and Cai, Zhigang},
  title = {Comparative Accuracy of Static vs Dynamic Guidance for Dental Implant Placement on Vascularized Bone Flap Reconstruction: A Retrospective Study},
  journal = {The International Journal of Oral & Maxillofacial Implants},
  year = {2025},
  doi = {10.11607/jomi.11330}
}
Start for free →