A Comparative Evaluation of Factors That Affect the Retentive Efficacy of a Partially Customized Abutment Specifically Designed for Single Implant Application in the Esthetic Zone

Jan C Kwan, Norman H Kwan

The International Journal of Oral & Maxillofacial Implants · 2024

DOI: 10.11607/jomi.10598 ↗

At a glance

Vergleichsstudie in The International Journal of Oral & Maxillofacial Implants, 2024. Written by Jan C Kwan and 1 co-authors. Major MEDLINE topics: Dental Abutments, Dental Implant-Abutment Design, Crowns, Esthetics, Dental. Cited 1 times so far (Crossref).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

PURPOSE: To compare the effect of taper, length, angle, and number of vertical axial walls on the retentive strength of a cemented crown on a partially customized hybrid abutment in the esthetic zone. MATERIALS AND METHODS: A total of 35 metal copings were used and divided into two groups. One group had 30 copings cemented to their corresponding 8-degree tapered abutment with lengths from 3 to 8 mm, increasing in 1-mm increments (5 copings per length). The other group had the remaining 5 copings and consisted of a standardized metal coping that matched a hexagonal abutment with 3-mm vertical axial walls and the sequential removal of 1, 2, and 3 contiguous vertical axial walls. Dislodgment tests were performed for all copings in both groups. Maximum retentive forces were measured in retentive strength (kgF), with a conversion factor of 9.807 N = 1 kgF. RESULTS: At each tapered abutment length, the retentive strength increased proportionally and was significantly different, ranging from 31.67 ± 4.10 kgF to 67.68 ± 11.22 kgF (F [5,24] = 20.46, P .05) in strength. CONCLUSIONS: A partially customized abutment with vertical axial walls on one side and a profile reduction on the opposite side can provide comparable retention to cemented copings at one-third the length and at one-sixth the surface area of an 8-mm abutment with an 8-degree taper.

Subjects

MeSH terms (MEDLINE)

Dental AbutmentsDental Implant-Abutment DesignCrownsEsthetics, DentalDental Stress AnalysisHumansDental Implants, Single-ToothDental Prosthesis RetentionMaterials TestingDental Prosthesis Design

Cite

APA

Kwan, J. C., & Kwan, N. H. (2024). A Comparative Evaluation of Factors That Affect the Retentive Efficacy of a Partially Customized Abutment Specifically Designed for Single Implant Application in the Esthetic Zone. The International Journal of Oral & Maxillofacial Implants. https://doi.org/10.11607/jomi.10598

Vancouver

Kwan JC, Kwan NH. A Comparative Evaluation of Factors That Affect the Retentive Efficacy of a Partially Customized Abutment Specifically Designed for Single Implant Application in the Esthetic Zone. The International Journal of Oral & Maxillofacial Implants. 2024. doi:10.11607/jomi.10598

BibTeX
@article{Kwan2024,
  author = {Kwan, Jan C and Kwan, Norman H},
  title = {A Comparative Evaluation of Factors That Affect the Retentive Efficacy of a Partially Customized Abutment Specifically Designed for Single Implant Application in the Esthetic Zone},
  journal = {The International Journal of Oral & Maxillofacial Implants},
  year = {2024},
  doi = {10.11607/jomi.10598}
}
Start for free →