A Comparative Evaluation of Factors That Affect the Retentive Efficacy of a Partially Customized Abutment Specifically Designed for Single Implant Application in the Esthetic Zone
The International Journal of Oral & Maxillofacial Implants · 2024
DOI: 10.11607/jomi.10598 ↗At a glance
Vergleichsstudie in The International Journal of Oral & Maxillofacial Implants, 2024. Written by Jan C Kwan and 1 co-authors. Major MEDLINE topics: Dental Abutments, Dental Implant-Abutment Design, Crowns, Esthetics, Dental. Cited 1 times so far (Crossref).
Abstract (original language)
PURPOSE: To compare the effect of taper, length, angle, and number of vertical axial walls on the retentive strength of a cemented crown on a partially customized hybrid abutment in the esthetic zone. MATERIALS AND METHODS: A total of 35 metal copings were used and divided into two groups. One group had 30 copings cemented to their corresponding 8-degree tapered abutment with lengths from 3 to 8 mm, increasing in 1-mm increments (5 copings per length). The other group had the remaining 5 copings and consisted of a standardized metal coping that matched a hexagonal abutment with 3-mm vertical axial walls and the sequential removal of 1, 2, and 3 contiguous vertical axial walls. Dislodgment tests were performed for all copings in both groups. Maximum retentive forces were measured in retentive strength (kgF), with a conversion factor of 9.807 N = 1 kgF. RESULTS: At each tapered abutment length, the retentive strength increased proportionally and was significantly different, ranging from 31.67 ± 4.10 kgF to 67.68 ± 11.22 kgF (F [5,24] = 20.46, P .05) in strength. CONCLUSIONS: A partially customized abutment with vertical axial walls on one side and a profile reduction on the opposite side can provide comparable retention to cemented copings at one-third the length and at one-sixth the surface area of an 8-mm abutment with an 8-degree taper.
Subjects
MeSH terms (MEDLINE)
Cite
APA
Kwan, J. C., & Kwan, N. H. (2024). A Comparative Evaluation of Factors That Affect the Retentive Efficacy of a Partially Customized Abutment Specifically Designed for Single Implant Application in the Esthetic Zone. The International Journal of Oral & Maxillofacial Implants. https://doi.org/10.11607/jomi.10598
Vancouver
Kwan JC, Kwan NH. A Comparative Evaluation of Factors That Affect the Retentive Efficacy of a Partially Customized Abutment Specifically Designed for Single Implant Application in the Esthetic Zone. The International Journal of Oral & Maxillofacial Implants. 2024. doi:10.11607/jomi.10598
BibTeX
@article{Kwan2024,
author = {Kwan, Jan C and Kwan, Norman H},
title = {A Comparative Evaluation of Factors That Affect the Retentive Efficacy of a Partially Customized Abutment Specifically Designed for Single Implant Application in the Esthetic Zone},
journal = {The International Journal of Oral & Maxillofacial Implants},
year = {2024},
doi = {10.11607/jomi.10598}
}
EUVIMED