EUVIMEDEUVIMED entdecken
Crossref

A Comparison of Denture Base Retention and Adaptation Between CAD/CAM and Conventional Fabrication Techniques

Mahmoud Amin Faty, Marwa Ezzat Sabet, Yasmine Galaleldin Thabet

The International Journal of Prosthodontics · 2023-07 · 36 (4) · 469-478

DOI: 10.11607/ijp.7193 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Prosthodontics, 2023-07. Verfasst von Mahmoud Amin Faty und 2 weiteren Autor:innen. Hauptthemen laut MEDLINE: Denture Bases, Mouth, Edentulous. Die Arbeit wurde bisher 27-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To assess the retention and adaptation of milled and printed denture bases in comparison to conventional ones. MATERIALS AND METHODS: A total of 24 completely edentulous patients were selected. For each patient, three maxillary denture bases were constructed according to different fabrication techniques, thus defining the three groups for comparison: group 1 consisted of denture bases constructed by a conventional technique, group 2 consisted of denture bases milled from prepolymerized blocks of PMMA, and group 3 consisted of denture bases fabricated by a 3D printing technique. A digital force gauge was used for measuring the retention of the denture bases intraorally, while Geomagic Control X 64 software was used to evaluate the adaptation of the denture bases with their corresponding master casts. Repeated-measures analysis of variance was used for comparison among the groups, followed by pairwise comparison with post hoc Bonferroni correction. The significance level was set at α = .05. RESULTS: Statistical analysis showed significant differences among the three groups regarding retention and adaptation. The highest values of retention and adaptation of denture bases were found in group 2 (milling group). CONCLUSION: Within the limitations of this study, the following could be concuded: milled denture bases demonstrated better retention and adaptation than the conventional heat-polymerized and printed denture bases, and the printed denture bases showed better adaptation but similar retention to conventional heat-polymerized denture bases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Denture BasesMouth, EdentulousHumansComputer-Aided DesignPrinting, Three-DimensionalResearch Design

Zitieren

APA

Faty, M. A., Sabet, M. E., & Thabet, Y. G. (2023). A Comparison of Denture Base Retention and Adaptation Between CAD/CAM and Conventional Fabrication Techniques. The International Journal of Prosthodontics, 36(4), 469-478. https://doi.org/10.11607/ijp.7193

Vancouver

Faty MA, Sabet ME, Thabet YG. A Comparison of Denture Base Retention and Adaptation Between CAD/CAM and Conventional Fabrication Techniques. The International Journal of Prosthodontics. 2023;36(4):469-478. doi:10.11607/ijp.7193

BibTeX
@article{Faty2023,
  author = {Faty, Mahmoud Amin and Sabet, Marwa Ezzat and Thabet, Yasmine Galaleldin},
  title = {A Comparison of Denture Base Retention and Adaptation Between CAD/CAM and Conventional Fabrication Techniques},
  journal = {The International Journal of Prosthodontics},
  year = {2023},
  volume = {36},
  number = {4},
  pages = {469--478},
  doi = {10.11607/ijp.7193}
}