EUVIMEDEUVIMED entdecken
Crossref

Frameless Intraoperative CT-Guided Deep Brain Stimulation: A Multi-Institutional Analysis of Stereotactic Accuracy and Operative Metrics

Matthan Tharakan, Kishore Balasubramanian, Rohan Aggarwal, Kiana Prather, Helen Shi, Ellen L Air, Brian Dalm, Arjun Khanna, Ryan Kochanski, Paul S Larson, Nader Pouratian, Andrew K Conner

Stereotactic and Functional Neurosurgery · 29.06.2026 · 1-12

DOI: 10.1159/000553285 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Stereotactic and Functional Neurosurgery, online erschienen am 29.06.2026. Verfasst von Matthan Tharakan und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA. Die Arbeit nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

MRI-guided stereotaxy provides high accuracy but is limited by the need for an interventional/intraoperative MRI environment and associated workflow complexity. ClearPoint Software v3.0 extends an established stereotactic workflow to a conventional operating room using intraoperative CT (iCT) imaging. We aimed to evaluate stereotactic accuracy and operative metrics of the ClearPoint frameless iCT image-guided system for deep brain stimulation (DBS) lead implantation.

Methods

We performed a multicenter retrospective review of consecutive DBS lead placement procedures supported by ClearPoint Neuro Navigation System Software Version 3.0 across 7 sites during a limited market release (February 1, 2025–May 1, 2025). Primary outcomes were radial targeting error (distance between planned trajectory endpoint and final device tip position in X-Y) and operative duration (skin incision to closure).

Results

Twenty-three procedures were analyzed. Median age was 67 years (range 32–89). Most cases were bilateral (87%, n = 20). Targets included subthalamic nucleus (39%, n = 9), ventral intermediate nucleus (39%, n = 9), and globus pallidus internus (22%, n = 5). Targeting accuracy was high, with median radial error of 0.20 mm on the left (range 0–1.60) and 0.20 mm on the right (range 0–1.0). Median operative duration was 127 min (range 69–225). Median intraoperative scans were 6, and procedures required a median of 2 adjustments per side.

Conclusion

In this first multi-institution report of ClearPoint Software v3.0 for DBS lead placement, the frameless iCT workflow demonstrated consistent submillimeter accuracy with favorable operative metrics in a standard operating room setting.

Schlagwörter

Stichwörter der Autor:innen

ClearPointDeep brain stimulationIntraoperative CTMovement disordersStereotactic accuracy

Autor:innen und Institutionen

  • Department of Neurosurgery, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA.
  • Texas A and M University College of Medicine, Houston, Texas, USA.
  • Department of Neurosurgery, Henry Ford Health, Detroit, Michigan, USA.
  • Department of Neurological Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
  • Department of Neurological Surgery, University of California San Diego Health, San Diego, California, USA.
  • Department of Neurosurgery, Baptist Health System, San Antonio, Texas, USA.

Zitieren

APA

Tharakan, M., Balasubramanian, K., Aggarwal, R., Prather, K., Shi, H., Air, E. L., Dalm, B., Khanna, A., Kochanski, R., Larson, P. S., Pouratian, N., & Conner, A. K. (2026). Frameless Intraoperative CT-Guided Deep Brain Stimulation: A Multi-Institutional Analysis of Stereotactic Accuracy and Operative Metrics. Stereotactic and Functional Neurosurgery, 1-12. https://doi.org/10.1159/000553285

Vancouver

Tharakan M, Balasubramanian K, Aggarwal R, Prather K, Shi H, Air EL, et al. Frameless Intraoperative CT-Guided Deep Brain Stimulation: A Multi-Institutional Analysis of Stereotactic Accuracy and Operative Metrics. Stereotactic and Functional Neurosurgery. 2026:1-12. doi:10.1159/000553285

BibTeX
@article{Tharakan2026,
  author = {Tharakan, Matthan and Balasubramanian, Kishore and Aggarwal, Rohan and Prather, Kiana and Shi, Helen and Air, Ellen L and Dalm, Brian and Khanna, Arjun and Kochanski, Ryan and Larson, Paul S and Pouratian, Nader and Conner, Andrew K},
  title = {Frameless Intraoperative CT-Guided Deep Brain Stimulation: A Multi-Institutional Analysis of Stereotactic Accuracy and Operative Metrics},
  journal = {Stereotactic and Functional Neurosurgery},
  year = {2026},
  pages = {1--12},
  doi = {10.1159/000553285}
}
Kostenlos starten →