Diagnostic Accuracy and Field for Improvement of Frameless Stereotactic Brain Biopsy: A Focus on Nondiagnostic Cases
Journal of Neurological Surgery Part A: Central European Neurosurgery · 01.01.2024 · 85 (01) · 048-061
DOI: 10.1055/a-1994-8033 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of Neurological Surgery Part A: Central European Neurosurgery, erschienen am 01.01.2024. Verfasst von Zhexi He und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Division of Neurosurgery, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, China. Hauptthemen laut MEDLINE: Brain, Brain Neoplasms. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 46 Literaturangaben.
Abstract (Originalsprache)
Background
The diagnostic accuracy of frameless stereotactic brain biopsy has been reported, but there is limited literature focusing on the reasons for nondiagnostic cases. In this study, we evaluate the diagnostic accuracy of frameless stereotactic brain biopsy, compare it with the current international standard, and review the field for improvement.
Methods
This is a retrospective analysis of consecutive, prospectively collected frameless stereotactic brain biopsies from 2007 to 2020. We evaluated the diagnostic accuracy of the frameless stereotactic brain biopsies using defined criteria. The biopsy result was classified as conclusive, inconclusive, or negative, based on the pathologic, radiologic, and clinical diagnosis concordance. For inconclusive or negative results, we further evaluated the preoperative planning and postoperative imaging to review the errors. A literature review for the diagnostic accuracy of frameless stereotactic biopsy was performed for the validity of our results.
Results
There were 106 patients with 109 biopsies performed from 2007 to 2020. The conclusive diagnosis was reached in 103 (94.5%) procedures. An inconclusive diagnosis was noted in four (3.7%) procedures and the biopsy was negative in two (1.9%) procedures. Symptomatic hemorrhage occurred in one patient (0.9%). There was no mortality in our series. Registration error (RE) and inaccurate targeting occurred in three trigonal lesions (2.8%), sampling of the nonrepresentative part of the lesion occurred in two cases (1.8%), and one biopsy (0.9%) for lymphoma was negative due to steroid treatment. The literature review suggested that our diagnostic accuracy was comparable with the published literature.
Conclusion
The frameless stereotactic biopsy is a safe procedure with high diagnostic accuracy only if meticulous preoperative planning and careful intraoperative registration is performed. The common pitfalls precluding a conclusive diagnosis are RE and biopsies at nonrepresentative sites.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Surgery, Division of Neurosurgery, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, China.
- Department of Neurosurgery, Tuen Mun Hospital, Hong Kong, China.
- Department of Imaging and Interventional Radiology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, China.
- Department of Anatomical & Cellular Pathology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, China.
- Department of Medicine and Therapeutics, Division of Neurology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, China.
ORCID-Profile: Zhexi He
Zitieren
APA
He, Z., Zhu, C. X. L., Chan, D. T. M., Cheung, T. C. Y., Ng, H. K., Mok, V. C. T., & Poon, W. S. (2024). Diagnostic Accuracy and Field for Improvement of Frameless Stereotactic Brain Biopsy: A Focus on Nondiagnostic Cases. Journal of Neurological Surgery Part A: Central European Neurosurgery, 85(01), 048-061. https://doi.org/10.1055/a-1994-8033
Vancouver
He Z, Zhu CXL, Chan DTM, Cheung TCY, Ng HK, Mok VCT, et al. Diagnostic Accuracy and Field for Improvement of Frameless Stereotactic Brain Biopsy: A Focus on Nondiagnostic Cases. Journal of Neurological Surgery Part A: Central European Neurosurgery. 2024;85(01):048-061. doi:10.1055/a-1994-8033
BibTeX
@article{He2024,
author = {He, Zhexi and Zhu, Cannon Xian Lun and Chan, Danny Tat Ming and Cheung, Tom Chi Yan and Ng, Ho-Keung and Mok, Vincent Chung Tong and Poon, Wai Sang},
title = {Diagnostic Accuracy and Field for Improvement of Frameless Stereotactic Brain Biopsy: A Focus on Nondiagnostic Cases},
journal = {Journal of Neurological Surgery Part A: Central European Neurosurgery},
year = {2024},
volume = {85},
number = {01},
pages = {048--061},
doi = {10.1055/a-1994-8033}
}
EUVIMED