Accuracy of Intraocular Lens Power Calculation Formulas in Cataract Eyes after Vitrectomy with Silicone Oil Tamponade: A Network Meta-Analysis
Ophthalmic Research · 05.03.2026 · 69 (1) · 85-97
DOI: 10.1159/000551331 ↗Kurz gefasst
Netzwerk-Metaanalyse in der Zeitschrift Ophthalmic Research, online erschienen am 05.03.2026. Verfasst von Peng Zhao und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Clinical Medicine, Shandong Second Medical University, Weifang, China. Hauptthemen laut MEDLINE: Vitrectomy, Silicone Oils, Lenses, Intraocular, Cataract. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Introduction
The aim of the study was to systematically compare the accuracy of artificial intelligence and traditional intraocular lens (IOL) calculation formulas in cataract eyes after vitrectomy with silicone oil tamponade.
Methods
PubMed, Cochrane, Embase, and Web of Science databases were searched to select relevant studies published up to October 29, 2025. A total of 12 formulas (SRK/T, Hoffer Q, Hoffer QST, Haigis, Barrett Universal II, Holladay I, Holladay II, RBF, LSF, EVO, Kane, and Pearl-DGS) were included for final comparison. The primary outcomes were the percentage of eyes with prediction errors (PE) within ± 0.50 D and ± 1.00 D.
Results
This meta-analysis included 7 studies comprising 1,060 eyes. Overall, compared to traditional formulas, newer formulas demonstrated relatively higher accuracy. The results indicated that among all the formulas being compared, the optimal formula was Kane. For the percentage of eyes with PE within ± 0.50 D, Kane had the highest precision. For the IOL power percentage within ± 1.00 D, EVO performed the best, with Kane also ranking highly. Furthermore, RBF also performed very well.
Conclusion
Kane and EVO appear to be better choices for silicone oil-filled eyes after vitrectomy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Clinical Medicine, Shandong Second Medical University, Weifang, China.
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China.
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China, xiuhuawan@126.com.
Zitieren
APA
Zhao, P., Li, M., Guo, Z. X., Tian, Z. Y., Zhang, J. S., Mao, Y. Y., Xin, Z., Li, Z. Y., & Wan, X. H. (2026). Accuracy of Intraocular Lens Power Calculation Formulas in Cataract Eyes after Vitrectomy with Silicone Oil Tamponade: A Network Meta-Analysis. Ophthalmic Research, 69(1), 85-97. https://doi.org/10.1159/000551331
Vancouver
Zhao P, Li M, Guo ZX, Tian ZY, Zhang JS, Mao YY, et al. Accuracy of Intraocular Lens Power Calculation Formulas in Cataract Eyes after Vitrectomy with Silicone Oil Tamponade: A Network Meta-Analysis. Ophthalmic Research. 2026;69(1):85-97. doi:10.1159/000551331
BibTeX
@article{Zhao2026,
author = {Zhao, Peng and Li, Meng and Guo, Zhao-Xing and Tian, Zhi-Yong and Zhang, Jing-Shang and Mao, Ying-Yan and Xin, Zheng and Li, Zhong-Yan and Wan, Xiu-Hua},
title = {Accuracy of Intraocular Lens Power Calculation Formulas in Cataract Eyes after Vitrectomy with Silicone Oil Tamponade: A Network Meta-Analysis},
journal = {Ophthalmic Research},
year = {2026},
volume = {69},
number = {1},
pages = {85--97},
doi = {10.1159/000551331}
}
EUVIMED