Correction of axial length measurement error by IOLMaster 700 could improve refractive prediction accuracy in silicone oil‐filled eyes

Jiaqing Zhang iD, Xiaotong Han iD, Aixia Jin, Yifan Zhang, Xiaoyun Chen, Zhenzhen Liu iD, Xiaozhang Qiu, Xuhua Tan, Lixia Luo iD, Yizhi Liu

Acta Ophthalmologica · 2024

DOI: 10.1111/aos.16627 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Ophthalmologica, 2024. Verfasst von Jiaqing Zhang und 9 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and …. Hauptthemen laut MEDLINE: Silicone Oils, Axial Length, Eye, Refraction, Ocular, Phacoemulsification. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: The Construction Project of High-Level Hospitals in Guangdong Province, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To determine whether correcting the axial length (AL) measurement error of the IOLMaster 700 could improve the refractive prediction accuracy in silicone oil‐filled eyes.

Methods

This study included 265 cataract patients (265 eyes) with silicone oil tamponade who were scheduled for phacoemulsification with intraocular lens (IOL) implantation. The performances of various formulas, including Barrett Universal II, Emmetropia Verifying Optical, Hoffer‐QST, Kane, Ladas Super Formula, Pearl‐DGS, Radial Basis Function and traditional formulas (Haigis, Hoffer Q, Holladay 1 and SRK/T), were evaluated. The refractive prediction errors (PE) calculated with measured AL (AL meas ) and corrected AL with silicone oil adjustment (SO AL ) were compared. Subgroup analysis was performed based on the AL meas (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Silicone OilsAxial Length, EyeRefraction, OcularPhacoemulsificationHumansFemaleMaleAgedMiddle AgedVisual AcuityBiometryRetrospective StudiesEndotamponadeReproducibility of ResultsRefractive ErrorsLens Implantation, IntraocularLenses, IntraocularAged, 80 and over

Stichwörter der Autor:innen

axial lengthcataractintraocular lens calculationprediction accuracysilicone oil‐filled eyes

Substanzen

Silicone Oils

Autor:innen und Institutionen

  • State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, China.
  • Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China.

ORCID-Profile: Jiaqing Zhang, Xiaotong Han, Zhenzhen Liu, Lixia Luo

Förderung

  • The Construction Project of High-Level Hospitals in Guangdong Province
  • National Natural Science Foundation of China

Zitieren

APA

Zhang, J., Han, X., Jin, A., Zhang, Y., Chen, X., Liu, Z., Qiu, X., Tan, X., Luo, L., & Liu, Y. (2024). Correction of axial length measurement error by IOLMaster 700 could improve refractive prediction accuracy in silicone oil‐filled eyes. Acta Ophthalmologica. https://doi.org/10.1111/aos.16627

Vancouver

Zhang J, Han X, Jin A, Zhang Y, Chen X, Liu Z, et al. Correction of axial length measurement error by IOLMaster 700 could improve refractive prediction accuracy in silicone oil‐filled eyes. Acta Ophthalmologica. 2024. doi:10.1111/aos.16627

BibTeX
@article{Zhang2024,
  author = {Zhang, Jiaqing and Han, Xiaotong and Jin, Aixia and Zhang, Yifan and Chen, Xiaoyun and Liu, Zhenzhen and Qiu, Xiaozhang and Tan, Xuhua and Luo, Lixia and Liu, Yizhi},
  title = {Correction of axial length measurement error by IOLMaster 700 could improve refractive prediction accuracy in silicone oil‐filled eyes},
  journal = {Acta Ophthalmologica},
  year = {2024},
  doi = {10.1111/aos.16627}
}
Kostenlos starten →