Simplifying biometry in oil-filled eyes: A novel formula for axial length calculation in eyes with 1000 cSt silicone oil

Monika Kapoor, Pradeep Venkatesh, Rohan Chawla, Shreyas Temkar, Esha Aggarwal

Indian Journal of Ophthalmology · 2023

DOI: 10.4103/ijo.ijo_2187_22 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Ophthalmology, 2023. Verfasst von Monika Kapoor und 4 weiteren Autor:innen. Beteiligte Einrichtung: Nethradhama Super Speciality Eye Hospital, Bengaluru, Karnataka, India. Hauptthemen laut MEDLINE: Phacoemulsification, Lenses, Intraocular. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To derive a formula for accurate axial length (AL) assessment using routine ultrasound in silicone oil-filled eyes, where optical biometry is unavailable or not possible.

Methods

This was a prospective, consecutive, nonrandomized study of 50 eyes of 50 patients conducted in a tertiary care hospital in North India. AL measurements were taken using both manual A-scan and IOL master, both in silicone oil-filled status and 3 weeks after silicone oil removal. A correction factor of 0.7 was used for AL adjustment in oil-filled eyes. The corrected AL (cAL) was compared with IOL master values in oil-filled eyes. Agreement analysis was carried out using Bland Altman plot. Linear regression analysis was done using uncorrected manual AL to find a new equation. Data was analyzed using Stata 14. A P value

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhacoemulsificationLenses, IntraocularMaleFemaleHumansChildAdolescentYoung AdultAdultMiddle AgedAgedAged, 80 and overSilicone OilsProspective StudiesEyeBiometryRefraction, OcularAxial Length, Eye

Stichwörter der Autor:innen

Axial length in oil-filled eyeaxial length in silicone oilbiometry in oil-filled eyesbiometry in silicone oilcataract in oil-filled eyespostvitrectomy cataract

Substanzen

Silicone Oils

Autor:innen und Institutionen

  • Nethradhama Super Speciality Eye Hospital, Bengaluru, Karnataka, India.
  • Rajendra Prasad Center for Ophthalmic Sciences, AIIMS, New Delhi, India.

Zitieren

APA

Kapoor, M., Venkatesh, P., Chawla, R., Temkar, S., & Aggarwal, E. (2023). Simplifying biometry in oil-filled eyes: A novel formula for axial length calculation in eyes with 1000 cSt silicone oil. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_2187_22

Vancouver

Kapoor M, Venkatesh P, Chawla R, Temkar S, Aggarwal E. Simplifying biometry in oil-filled eyes: A novel formula for axial length calculation in eyes with 1000 cSt silicone oil. Indian Journal of Ophthalmology. 2023. doi:10.4103/ijo.ijo_2187_22

BibTeX
@article{Kapoor2023,
  author = {Kapoor, Monika and Venkatesh, Pradeep and Chawla, Rohan and Temkar, Shreyas and Aggarwal, Esha},
  title = {Simplifying biometry in oil-filled eyes: A novel formula for axial length calculation in eyes with 1000 cSt silicone oil},
  journal = {Indian Journal of Ophthalmology},
  year = {2023},
  doi = {10.4103/ijo.ijo_2187_22}
}
Kostenlos starten →