Photon Counting Computed Tomography with the Radiation Dose of a Chest X-Ray: Feasibility and Diagnostic Yield
Respiration · 2024
DOI: 10.1159/000536065 ↗Kurz gefasst
Fachartikel in der Zeitschrift Respiration, 2024. Verfasst von Sabine Dettmer und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Pneumonia. Die Arbeit wurde bisher 22-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Photon counting (PC) detectors allow a reduction of the radiation dose in CT. Chest X-ray (CXR) is known to have a low sensitivity and specificity for detection of pneumonic infiltrates. The aims were to establish an ultra-low-dose CT (ULD-CT) protocol at a PC-CT with the radiation dose comparable to the dose of a CXR and to evaluate its clinical yield in patients with suspicion of pneumonia.
Methods
A ULD-CT protocol was established with the aim to meet the radiation dose of a CXR. In this retrospective study, all adult patients who received a ULD-CT of the chest with suspected pneumonia were included. Radiation exposure of ULD-CT and CXR was calculated. The clinical significance (new diagnosis, change of therapy, additional findings) and limitations were evaluated by a radiologist and a pulmonologist considering previous CXR and clinical data.
Results
Twenty-seven patients (70% male, mean age 68 years) were included. With our ULD-CT protocol, the radiation dose of a CXR could be reached (mean radiation exposure 0.11 mSv). With ULD-CT, the diagnosis changed in 11 patients (41%), there were relevant additional findings in 4 patients (15%), an infiltrate (particularly fungal infiltrate under immunosuppression) could be ruled out with certainty in 10 patients (37%), and the therapy changed in 10 patients (37%). Two patients required an additional CT with contrast medium to rule out a pulmonary embolism or pleural empyema.
Conclusions
With ULD-CT, the radiation dose of a CXR could be reached while the clinical impact is higher with change in diagnosis in 41%.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.
- Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Center for Lung Research (DZL), Hannover, Germany.
- Emergency Department, Hannover Medical School, Hannover, Germany.
- Department of Respiratory Medicine and Infectious Diseases, Hannover Medical School, Hannover, Germany.
Zitieren
APA
Dettmer, S., Werncke, T., Mitkovska, V. N., Brod, T., Joean, O., Vogel-Claussen, J., Wacker, F., Welte, T., & Rademacher, J. (2024). Photon Counting Computed Tomography with the Radiation Dose of a Chest X-Ray: Feasibility and Diagnostic Yield. Respiration. https://doi.org/10.1159/000536065
Vancouver
Dettmer S, Werncke T, Mitkovska VN, Brod T, Joean O, Vogel-Claussen J, et al. Photon Counting Computed Tomography with the Radiation Dose of a Chest X-Ray: Feasibility and Diagnostic Yield. Respiration. 2024. doi:10.1159/000536065