EUVIMEDEUVIMED entdecken
Übersichtsarbeit

The rise of modern tonometry: the evolution of intraocular pressure measurement

Piervincenzo Rizzo, Isabella N Romano, Ali Komaie, Ian Conner

Expert Review of Medical Devices · 01.11.2026 · 1-20

DOI: 10.1080/17434440.2026.2754635 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Expert Review of Medical Devices, online erschienen am 01.11.2026. Verfasst von Piervincenzo Rizzo und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Civil and Environmental Engineering, SWANSON School of Engineering, University of Pittsburgh, Pittsburgh, PA, USA. Die Arbeit nennt 97 Literaturangaben. Gefördert von: U.S. National Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Intraocular pressure (IOP) is the primary biomarker for the diagnosis and management of glaucoma, a progressive optic neuropathy and the second leading cause of blindness worldwide. Its pathophysiology involves an imbalance between aqueous humor production and drainage that elevates IOP, ultimately damaging the optic nerve. IOP exhibits substantial circadian fluctuations, and single-point clinical measurements frequently fail to capture peak diurnal pressure, thereby underestimating the risk of disease progression, delaying necessary intervention, and obscuring patient compliance with pharmaceutical therapies. AREAS COVERED: This review synthesizes historical, contemporary, and emerging IOP measurement technologies, examining their underlying physical principles, clinical utility, and limitations, with particular emphasis on their capacity to characterize the dynamic, time-varying nature of IOP. The search drew on Google Scholar and manufacturers' websites, focusing on physical principles and systems not yet FDA-approved or clinically tested. EXPERT OPINION: A critical unmet clinical need exists for accessible home-monitoring solutions. The ideal device would be non-invasive, affordable, and user-friendly, requiring neither topical anesthesia nor sterilization, and would support remote data transmission to facilitate continuous patient-clinician communication. This unmet need offers an opportunity for engineers and healthcare professionals to develop new technologies to help people avoiding travels to and decongest doctors' offices.

Schlagwörter

Stichwörter der Autor:innen

Intraocular pressure measurementsbiomedical engineeringglaucomamedical devicestonometry

Autor:innen und Institutionen

  • Department of Civil and Environmental Engineering, SWANSON School of Engineering, University of Pittsburgh, Pittsburgh, PA, USA.
  • Department of Ophthalmology, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA.

Förderung

  • U.S. National Science Foundation

Zitieren

APA

Rizzo, P., Romano, I. N., Komaie, A., & Conner, I. (2026). The rise of modern tonometry: the evolution of intraocular pressure measurement. Expert Review of Medical Devices, 1-20. https://doi.org/10.1080/17434440.2026.2754635

Vancouver

Rizzo P, Romano IN, Komaie A, Conner I. The rise of modern tonometry: the evolution of intraocular pressure measurement. Expert Review of Medical Devices. 2026:1-20. doi:10.1080/17434440.2026.2754635

BibTeX
@article{Rizzo2026,
  author = {Rizzo, Piervincenzo and Romano, Isabella N and Komaie, Ali and Conner, Ian},
  title = {The rise of modern tonometry: the evolution of intraocular pressure measurement},
  journal = {Expert Review of Medical Devices},
  year = {2026},
  pages = {1--20},
  doi = {10.1080/17434440.2026.2754635}
}
Kostenlos starten →