Accuracy of Toric Intraocular Lens Implantation Using Three‐Random‐Point Marking Method: A Prospective Pilot Study
Journal of Ophthalmology · 2026-01 · 2026 (1)
DOI: 10.1155/joph/7948866 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Ophthalmology, online erschienen am 27.04.2026. Verfasst von Shuilian Chen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Southern Medical University, Guangzhou, C…. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Guangdong Province, Guangzhou Science and Technology Program key projects.
Abstract (Originalsprache)
Introduction
This study aimed to compare the accuracy of three‐random‐point (TRP) marking method with the slit‐lamp horizontal meridian (SHM) marking method by using an image‐guided system in the positioning of a toric intraocular lens (IOL). Materials and Methods A total of 60 eyes of 54 patients who underwent cataract surgery were prospectively randomized into 3 groups (each group included 20 eyes: Group 1, novice doctor and dilated pupil patient; Group 2, novice doctor and small pupil patient; and Group 3, experienced doctor and small pupil patient). Every patient was marked three points (horizontal two points and random third point) in corneal limbus with a staining blunt needle and then measured by the iTrace system. The axis deviations from the SHM method (axis A, horizontal two points method) and the TRP method (axis B, three points method) were measured by the digital image‐guided navigation system.
Results
The axis deviations of each group showed a significant difference between the SHM and TRP marking methods (Group 1: SHM method: 3.05° ± 2.58° and TRP method: 0.85° ± 0.93°, p < 0.01; Group 2: SHM method: 2.15° ± 2.35° and TRP method: 1.05° ± 1.57°, p < 0.05; and Group 3: SHM method: 1.00° ± 1.84° and TRP method: 0.45° ± 1.23°, p < 0.05).
Conclusions
The TRP marking method using the iTrace aberrometer was found to be more effective and more accurate than SHM marking method in the positioning of toric IOLs before surgery. Trial Registration: Chinese Clinical Trial Registry: ChiCTR2600121114
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Southern Medical University, Guangzhou, China, fimmu.com.
- Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China, gdghospital.org.cn.
- Department of Ophthalmology, Nanfang Hospital, Southern Medical University, Guangzhou, China, fimmu.com.
ORCID-Profile: Shuilian Chen, Yiliang Liu, Fulong Luo, Hongyang Zhang, Yongyi Niu
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Guangdong Province
- Guangzhou Science and Technology Program key projects
Zitieren
APA
Chen, S., Liu, Y., Luo, F., Zhang, H., & Niu, Y. (2026). Accuracy of Toric Intraocular Lens Implantation Using Three‐Random‐Point Marking Method: A Prospective Pilot Study. Journal of Ophthalmology, 2026(1). https://doi.org/10.1155/joph/7948866
Vancouver
Chen S, Liu Y, Luo F, Zhang H, Niu Y. Accuracy of Toric Intraocular Lens Implantation Using Three‐Random‐Point Marking Method: A Prospective Pilot Study. Journal of Ophthalmology. 2026;2026(1). doi:10.1155/joph/7948866
BibTeX
@article{Chen2026,
author = {Chen, Shuilian and Liu, Yiliang and Luo, Fulong and Zhang, Hongyang and Niu, Yongyi},
title = {Accuracy of Toric Intraocular Lens Implantation Using Three‐Random‐Point Marking Method: A Prospective Pilot Study},
journal = {Journal of Ophthalmology},
year = {2026},
volume = {2026},
number = {1},
doi = {10.1155/joph/7948866}
}
EUVIMED