Fachartikel in der Zeitschrift International Journal of Dentistry, online erschienen am 12.06.2026. Verfasst von Solmaz Valizadeh und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Radiology, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran, sbmu.ac.ir. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
Artifacts from dental implants impact the clarity of cone‐beam computed tomography (CBCT) scans, posing challenges to radiographic detection in adjacent areas. The aim of this in vitro study is to examine the effect of angling a phantom incorporating implant fixtures on the amount of metal artifacts in CBCT scans. Materials and Methods Three titanium fixtures, each with a diameter of 4.2 mm and a height of 12 mm were positioned within a bone block made of bovine mandibular bone. The specimen was placed on a surveyor table. The device was employed to regulate the rotation of the phantom along anterior–posterior ( α ) and right‐left ( β ) axes. For each axis, the sample was scanned at three angles (0°, 15°, and 30°), resulting in a total of 12 scans. Each scan includes 10 regions of interest (ROIs). The absolute gray values (GVs) of all ROIs were determined at two levels (apical and coronal), and the mean and standard deviation (SD) were calculated. Using SPSS version 23 software, two‐way ANOVA was employed to examine the impact of the angle and plane of rotation on the quantity of metal artifacts.
Results
Higher ΔGV was seen as the angle increased in the alpha plane, while in the beta plane, the highest ΔGV occurred at 15°. At the apical level, mean ΔGV in the alpha plane (0.036) was higher than in the beta plane (0.007), whereas at the coronal level it was higher in the beta plane (0.186 vs. 0.087). Corresponding p ‐values for placement angle, rotation plane, and interaction of angle in the rotation plane were 0.734, 0.519, and 0.811 at the apical level and 0.254, 0.448, and 0.305 at the coronal level.
Conclusion
Altering the implant placement angle and rotation plane did not significantly impact the quantity of metal artifacts in CBCT images.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran, sbmu.ac.ir.
- Department of Prosthodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran, sbmu.ac.ir.
- Department of Periodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran, sbmu.ac.ir.
- Research Committee, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran, sbmu.ac.ir.
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran, umsha.ac.ir.
ORCID-Profile: Solmaz Valizadeh, Mahkameh Moshfeghi, Behzad Houshmand, Seyed Sepehr Mirebeigi-Jamasbi, Maedeh Asnaashari
Zitieren
APA
Valizadeh, S., Moshfeghi, M., Bahrani, Z., Houshmand, B., Mirebeigi-Jamasbi, S. S., & Asnaashari, M. (2026). Effect of Phantom Containing Implants Angulation on the Amount of Metal Artifacts Around the Implants in CBCT Images. International Journal of Dentistry, 2026(1). https://doi.org/10.1155/ijod/8828788
Vancouver
Valizadeh S, Moshfeghi M, Bahrani Z, Houshmand B, Mirebeigi-Jamasbi SS, Asnaashari M. Effect of Phantom Containing Implants Angulation on the Amount of Metal Artifacts Around the Implants in CBCT Images. International Journal of Dentistry. 2026;2026(1). doi:10.1155/ijod/8828788
BibTeX
@article{Valizadeh2026,
author = {Valizadeh, Solmaz and Moshfeghi, Mahkameh and Bahrani, Zeinab and Houshmand, Behzad and Mirebeigi-Jamasbi, Seyed Sepehr and Asnaashari, Maedeh},
title = {Effect of Phantom Containing Implants Angulation on the Amount of Metal Artifacts Around the Implants in CBCT Images},
journal = {International Journal of Dentistry},
year = {2026},
volume = {2026},
number = {1},
doi = {10.1155/ijod/8828788}
}
EUVIMED