Impact of Metal Artifact Reduction on the Diagnosis of Peri-Implant Defects Around Zirconia and Titanium Implants: A CBCT Pilot Study

Mahsa Moannaei, Mojdeh Mehdizadeh, Farnaz Mirrashidi, Mohammad Hossein Manouchehri, Sepehr Naghdi, Amirhossein Moaddabi, Nima Malek Hosseini, Gianrico Spagnuolo, Francesco Giordano, Parisa Soltani

Oral · 03.07.2026 · 6 (4) · 83

DOI: 10.3390/oral6040083 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Oral, online erschienen am 03.07.2026. Verfasst von Mahsa Moannaei und 9 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Isfahan University of Medical Sciences.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Metal artifacts from dental implants degrade CBCT image quality and may impair detection of peri-implant bone defects. Zirconia implants produce stronger artifacts than titanium due to its higher atomic number. This study evaluated the impact of a native MAR algorithm (SMARF) on CBCT detection of buccal fenestration and dehiscence of varying sizes adjacent to zirconia versus titanium implants.

Methods

In this ex vivo pilot study, two 4 mm × 12 mm implants (one titanium and one zirconia) were implanted in a dry human mandible. Artificial fenestration and dehiscence defects were created at the buccal surface of right and left premolar regions, in three sizes (small 2 mm × 2 mm× 1 mm; medium 2 mm × 4 mm× 1 mm; large 2 mm × 6 mm× 1 mm). Scans were acquired with a Papaya 3D (Genoray) CBCT using a single-tooth FOV (4 cm× 4 cm × 5 cm), 83 kVp, 10 mA, 0.1 mm voxel; each condition was imaged with MAR on and off (six repeats each). Two trained observers scored defect presence on a five-point Likert scale. Sensitivity, specificity, inter- and intraobserver agreement (Cohen’s kappa), and comparisons across conditions were calculated.

Results

Interobserver κ = 0.65 (substantial); intraobserver κ = 0.87–1.00 (excellent). For titanium implants, sensitivity and specificity were 100% across all defect types, sizes, and MAR settings. For zirconia implants, fenestration sensitivity with MAR off increased with size (small 50%, medium 75%, large 100%); MAR on raised sensitivity to 100% for all sizes, with a significant improvement for small fenestrations (p = 0.005). Dehiscence sensitivity for zirconia was 100% across sizes and MAR conditions. Specificity for zirconia defects was 83.3% with MAR off and decreased to 66.6% with MAR on (p = 0.07).

Conclusions

With the Papaya 3D system used in this pilot study, MAR was unnecessary for defect detection adjacent to titanium implants but affected performance for zirconia implants: MAR increased sensitivity for small fenestrations while reducing specificity (although not statistically significant). Clinicians should weigh the sensitivity–specificity trade off when applying MAR around zirconia implants.

Förderung

  • Isfahan University of Medical Sciences

Zitieren

APA

Moannaei, M., Mehdizadeh, M., Mirrashidi, F., Manouchehri, M. H., Naghdi, S., Moaddabi, A., Hosseini, N. M., Spagnuolo, G., Giordano, F., & Soltani, P. (2026). Impact of Metal Artifact Reduction on the Diagnosis of Peri-Implant Defects Around Zirconia and Titanium Implants: A CBCT Pilot Study. Oral, 6(4), 83. https://doi.org/10.3390/oral6040083

Vancouver

Moannaei M, Mehdizadeh M, Mirrashidi F, Manouchehri MH, Naghdi S, Moaddabi A, et al. Impact of Metal Artifact Reduction on the Diagnosis of Peri-Implant Defects Around Zirconia and Titanium Implants: A CBCT Pilot Study. Oral. 2026;6(4):83. doi:10.3390/oral6040083

BibTeX
@article{Moannaei2026,
  author = {Moannaei, Mahsa and Mehdizadeh, Mojdeh and Mirrashidi, Farnaz and Manouchehri, Mohammad Hossein and Naghdi, Sepehr and Moaddabi, Amirhossein and Hosseini, Nima Malek and Spagnuolo, Gianrico and Giordano, Francesco and Soltani, Parisa},
  title = {Impact of Metal Artifact Reduction on the Diagnosis of Peri-Implant Defects Around Zirconia and Titanium Implants: A CBCT Pilot Study},
  journal = {Oral},
  year = {2026},
  volume = {6},
  number = {4},
  pages = {83},
  doi = {10.3390/oral6040083}
}
Kostenlos starten →