EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An interactive task-based method for the avoidance of metal artifacts in CBCT

Maximilian Rohleder, Mareike Thies, Sophie Riedl, Benno Bullert, Jula Gierse, Maxim Privalov, Eric Mandelka, Sven Vetter, Andreas Maier, Bjoern Kreher

International Journal of Computer Assisted Radiology and Surgery · 23.05.2024 · 19 (7) · 1399-1407

DOI: 10.1007/s11548-024-03103-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, online erschienen am 23.05.2024. Verfasst von Maximilian Rohleder und 9 weiteren Autor:innen. Beteiligte Einrichtung: Pattern Recognition Lab, Friedrich-Alexander-University, Martenstraße 3, Erlangen, 91058, Germany. Maxi.Rohleder@fau.de. Hauptthemen laut MEDLINE: Artifacts, Cone-Beam Computed Tomography, Metals, Cadaver. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Friedrich-Alexander-Universität Erlangen-Nürnberg.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Intraoperative cone-beam CT imaging enables 3D validation of implant positioning and fracture reduction for orthopedic and trauma surgeries. However, the emergence of metal artifacts, especially in the vicinity of metallic objects, severely degrades the clinical value of the imaging modality. In previous works, metal artifact avoidance (MAA) methods have been shown to reduce metal artifacts by adapting the scanning trajectory. Yet, these methods fail to translate to clinical practice due to remaining methodological constraints and missing workflow integration.

Methods

In this work, we propose a method to compute the spatial distribution and calibrated strengths of expected artifacts for a given tilted circular trajectory. By visualizing this as an overlay changing with the C-Arm’s tilt, we enable the clinician to interactively choose an optimal trajectory while factoring in the procedural context and clinical task. We then evaluate this method in a realistic human cadaver study and compare the achieved image quality to acquisitions optimized using global metrics.

Results

We assess the effectiveness of the compared methods by evaluation of image quality gradings of depicted pedicle screws. We find that both global metrics as well as the proposed visualization of artifact distribution enable a drastic improvement compared to standard non-tilted scans. Furthermore, the novel interactive visualization yields a significant improvement in subjective image quality compared to the state-of-the-art global metrics. Additionally we show that by formulating an imaging task, the proposed method allows to selectively optimize image quality and avoid artifacts in the region of interest.

Conclusion

We propose a method to spatially resolve predicted artifacts and provide a calibrated measure for artifact strength grading. This interactive MAA method proved practical and effective in reducing metal artifacts in the conducted cadaver study. We believe this study serves as a crucial step toward clinical application of an MAA system to improve image quality and enhance the clinical validation of implant placement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArtifactsCone-Beam Computed TomographyMetalsCadaverHumansImaging, Three-DimensionalPedicle Screws

Stichwörter der Autor:innen

CT Trajectory OptimizationCone-beam CTHuman Computer InteractionMetal Artifact Avoidance

Substanzen

Metals

Autor:innen und Institutionen

  • Pattern Recognition Lab, Friedrich-Alexander-University, Martenstraße 3, Erlangen, 91058, Germany. Maxi.Rohleder@fau.de.
  • Siemens Healthineers AG, Siemensstraße 1, Forchheim, 91301, Germany. Maxi.Rohleder@fau.de.
  • Pattern Recognition Lab, Friedrich-Alexander-University, Martenstraße 3, Erlangen, 91058, Germany.
  • Siemens Healthineers AG, Siemensstraße 1, Forchheim, 91301, Germany.
  • Department for Trauma and Orthopaedic Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Straße 13, Ludwigshafen am Rhein, 67071, Germany.

Förderung

  • Friedrich-Alexander-Universität Erlangen-Nürnberg

Zitieren

APA

Rohleder, M., Thies, M., Riedl, S., Bullert, B., Gierse, J., Privalov, M., Mandelka, E., Vetter, S., Maier, A., & Kreher, B. (2024). An interactive task-based method for the avoidance of metal artifacts in CBCT. International Journal of Computer Assisted Radiology and Surgery, 19(7), 1399-1407. https://doi.org/10.1007/s11548-024-03103-4

Vancouver

Rohleder M, Thies M, Riedl S, Bullert B, Gierse J, Privalov M, et al. An interactive task-based method for the avoidance of metal artifacts in CBCT. International Journal of Computer Assisted Radiology and Surgery. 2024;19(7):1399-1407. doi:10.1007/s11548-024-03103-4

BibTeX
@article{Rohleder2024,
  author = {Rohleder, Maximilian and Thies, Mareike and Riedl, Sophie and Bullert, Benno and Gierse, Jula and Privalov, Maxim and Mandelka, Eric and Vetter, Sven and Maier, Andreas and Kreher, Bjoern},
  title = {An interactive task-based method for the avoidance of metal artifacts in CBCT},
  journal = {International Journal of Computer Assisted Radiology and Surgery},
  year = {2024},
  volume = {19},
  number = {7},
  pages = {1399--1407},
  doi = {10.1007/s11548-024-03103-4}
}
Kostenlos starten →