EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparison of Anatomical and Indication‐Based Diagnostic Reference Levels (DRLs) in Head CT Imaging: Implications for Radiation Dose Management

Benard Ohene-Botwe iD, Samuel Anim-Sampong iD, Robert Saizi iD

International Journal of Biomedical Imaging · 2025-01 · 2025 (1)

DOI: 10.1155/ijbi/6464273 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Biomedical Imaging, online erschienen am 19.03.2025. Verfasst von Benard Ohene-Botwe und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Midwifery and Radiography, School of Health & Psychological Sciences, City, University of London, London, UK. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Many diagnostic reference levels (DRLs) in computed tomography (CT) imaging are based mainly on anatomical locations and often overlook variations in radiation exposure due to different clinical indications. While indication‐based DRLs, derived from dose descriptors like volume‐weighted CT dose index (CTDI vol ) and dose length product (DLP), are recommended for optimising patient radiation exposure, many studies still use anatomical‐based DRL values. This study is aimed at quantifying the differences between anatomical and indication‐based DRL values in head CT imaging and assessing its implications for radiation dose management. This will support the narrative when explaining the distinction between indication‐based DRLs and anatomical DRLs for patients’ dose management.

Methods

Employing a retrospective quantitative study design, we developed and compared anatomical and common indication‐based DRL values using a dataset of head CT scans with similar characteristics. The indications included in the study were brain tumor/intracranial space‐occupying lesion (ISOL), head injury/trauma, stroke, and anatomical examinations. Data analysis was conducted using SPSS Version 29.

Results

The findings suggest that using anatomical‐based DLP DRL values for CT head examinations leads to underestimations in the median, 25th percentile, and 75th percentile values of head injury/trauma by 20.2%, 30.0%, and 14.5% in single‐phase CT head procedures. Conversely, for the entire examination, using anatomical‐based DLP DRL as a benchmark for CT stroke DRL overestimates median, 25th percentile, and 75th percentile values by 18.3%, 23.9%, and 13.5%. Brain tumor/ISOL DL P values are underestimated by 62.6%, 60.4%, and 71.8%, respectively.

Conclusion

The study highlights that using anatomical DLP DRL values for specific indications in head CT scans can lead to underestimated or overestimated DL P values, making them less reliable for radiation management compared to indication‐based DRLs. Therefore, it is imperative to promote the establishment and use of indication‐based DRLs for more accurate dose management in CT imaging.

Schlagwörter

Stichwörter der Autor:innen

anatomicalcomputed tomographydiagnostic reference levelsdifferencesindication based

Autor:innen und Institutionen

  • Department of Midwifery and Radiography, School of Health & Psychological Sciences, City, University of London, London, UK.
  • Department of Radiography, University of Ghana, Accra, Ghana.
  • Department of Radiology, Queen Elizabeth Central Hospital, Blantyre, Malawi.

ORCID-Profile: Benard Ohene-Botwe, Samuel Anim-Sampong, Robert Saizi

Zitieren

APA

Ohene-Botwe, B., Anim-Sampong, S., & Saizi, R. (2025). Comparison of Anatomical and Indication‐Based Diagnostic Reference Levels (DRLs) in Head CT Imaging: Implications for Radiation Dose Management. International Journal of Biomedical Imaging, 2025(1). https://doi.org/10.1155/ijbi/6464273

Vancouver

Ohene-Botwe B, Anim-Sampong S, Saizi R. Comparison of Anatomical and Indication‐Based Diagnostic Reference Levels (DRLs) in Head CT Imaging: Implications for Radiation Dose Management. International Journal of Biomedical Imaging. 2025;2025(1). doi:10.1155/ijbi/6464273

BibTeX
@article{OheneBotwe2025,
  author = {Ohene-Botwe, Benard and Anim-Sampong, Samuel and Saizi, Robert},
  title = {Comparison of Anatomical and Indication‐Based Diagnostic Reference Levels (DRLs) in Head CT Imaging: Implications for Radiation Dose Management},
  journal = {International Journal of Biomedical Imaging},
  year = {2025},
  volume = {2025},
  number = {1},
  doi = {10.1155/ijbi/6464273}
}
Kostenlos starten →