Fachartikel in der Zeitschrift BioMed Research International, online erschienen am 05.08.2026. Verfasst von Antonio Scarano und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Innovative Technology in Medicine and Dentistry, University of Chieti-Pescara, Chieti, Italy, unich.it. Hauptthemen laut MEDLINE: Aluminum Oxide, Dental Implants. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Università degli Studi G. d'Annunzio Chieti - Pescara, CRUI-CARE.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Osseointegration is a fundamental requirement for the long‐term success of dental implants. Several implant systems have demonstrated excellent clinical outcomes over time, confirming their high reliability in the treatment of edentulism, even in patients with chronic disease. The success of these devices is closely linked to the characteristics of the implant surface, which directly influence the biological response of the surrounding bone.

Objectives

The primary objective of this study was to investigate the presence of foreign material on the surface of dental implants following aluminum oxide sandblasting and subsequent surface treatment procedures. This analysis was conducted using scanning electron microscopy (SEM) and energy‐dispersive x‐ray spectroscopy (EDS) to characterize the surface morphology and elemental composition. The secondary objective was to evaluate the cytotoxic potential of the implant surface through in vitro assays, in accordance with ISO 10993‐5:2009, to assess its biocompatibility and suitability for clinical application. Materials and Methods Twenty threaded screw‐shaped sandblasted Grade 5 titanium dental implants Dental Implant Advance 4.2 × 11.5 mm (Kinetical Implant, Buenos Aires, Argentina) for SEM combined with EDS, in order to identify the presence of possible organic contaminants or residues of the surface treatment process. Another 20 dental implant samples of the same type (4.2 × 11.5 mm) were used for the cytotoxicity test.

Result

SEM analysis revealed a surface morphology consistent with sandblasting treatment, characterized by uniform roughness. However, particles with irregular shapes were observed in certain areas. Aluminum oxide particles were observed adhering to the surface of the implant. The cell viability percentages for each group were as follows: vehicle, 100.0%; negative control (HDPE), 96.0%; positive control (latex), 0.24%; and test samples, 96.9%. Based on the results obtained, the test sample did not show any relevant cytotoxic effects, maintaining a cell viability above 70% and OD values comparable to the negative controls. Therefore, it can be considered noncytotoxic in accordance with ISO 10993‐5.

Conclusion

In conclusion, these findings indicate that the presence of residual alumina particles, resulting from the sandblasting process, does not exert a negative impact on cellular viability. Consequently, such residues can be considered not cytotoxic under the tested conditions, supporting the biocompatibility of the implant surface.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aluminum OxideDental ImplantsMicroscopy, Electron, ScanningAnimalsSurface PropertiesSpectrometry, X-Ray EmissionHumansMaterials TestingTitaniumCell SurvivalOsseointegrationMice

Stichwörter der Autor:innen

aluminum oxideblasting procedurecontaminationosseointegrationsurface cleanliness

Substanzen

Aluminum OxideDental ImplantsTitanium

Autor:innen und Institutionen

  • Department of Innovative Technology in Medicine and Dentistry, University of Chieti-Pescara, Chieti, Italy, unich.it.
  • Zirconia Implant Research Group (Z.I.R.G), International Academy of Ceramic Implantology, Silver Spring, Maryland, USA, iaoci.com.
  • Department of Biotechnology, Universidad Católica de Murcia, Murcia, Spain.
  • Department of Life, Health and Environmental Sciences, University of L'Aquila, L'Aquila, Italy, univaq.it.
  • Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy, unifg.it.

ORCID-Profile: Antonio Scarano, Sergio Alexandre Gehrke, Sergio Rexhep Tari, Tonino Traini, Filiberto Mastrangelo

Förderung

  • Università degli Studi G. d'Annunzio Chieti - Pescara
  • CRUI-CARE

Zitieren

APA

Scarano, A., Gehrke, S. A., Falisi, G., Tari, S. R., Traini, T., & Mastrangelo, F. (2026). Distribution and Chemical Nature of Al 2 O 3 Residues Following the Sandblasting Process: An In Vitro Study Using SEM, EDS, and Cytotoxicity Analysis. BioMed Research International, 2026(1). https://doi.org/10.1155/bmri/8875067

Vancouver

Scarano A, Gehrke SA, Falisi G, Tari SR, Traini T, Mastrangelo F. Distribution and Chemical Nature of Al 2 O 3 Residues Following the Sandblasting Process: An In Vitro Study Using SEM, EDS, and Cytotoxicity Analysis. BioMed Research International. 2026;2026(1). doi:10.1155/bmri/8875067

BibTeX
@article{Scarano2026,
  author = {Scarano, Antonio and Gehrke, Sergio Alexandre and Falisi, Giovanni and Tari, Sergio Rexhep and Traini, Tonino and Mastrangelo, Filiberto},
  title = {Distribution and Chemical Nature of Al 2 O 3 Residues Following the Sandblasting Process: An In Vitro Study Using SEM, EDS, and Cytotoxicity Analysis},
  journal = {BioMed Research International},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1155/bmri/8875067}
}
Kostenlos starten →