EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Cleaning Efficacy and Surface Alterations of Titanium and Zirconia Implant Abutments Following Mechanical Instrumentation: An In Vitro Study

Marina Salah Kamel, Axel Spahr, Tim Badgery-Parker iD, Tihana Divnić-Resnik iD

Clinical Oral Implants Research · 2026-11 · 37 (11) · 1402-1419

DOI: 10.1111/clr.70182 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Oral Implants Research, online erschienen am 25.09.2026. Verfasst von Marina Salah Kamel und 3 weiteren Autor:innen. Beteiligte Einrichtung: Discipline of Periodontics, Sydney Dental School, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia. Hauptthemen laut MEDLINE: Titanium, Zirconium, Dental Abutments, Dental Implants. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Sydney Dental School Research Committee (SEED), The University of Sydney Nano Institute (Sydney Nano), Science for Equity, Empowerment and Development Division.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate the cleaning efficacy, quantitative and qualitative surface modifications of titanium (Ti) and zirconia (Zr) abutments following instrumentation with twelve mechanical instrumentation modalities. Materials and Methods Twenty‐four Ti and twenty‐four Zr abutments were divided by marginal grooves into 36 test and 12 control surfaces per material. Test abutments were mounted in a custom peri‐implant mucositis model and treated in triplicate with twelve modalities: glycine (GPAP) and erythritol (EPAP‐5 s and 20 s) air‐polishing; prophylaxis cup with paste; plastic, titanium and stainless‐steel (SS) curettes; and titanium, polyether‐ether‐ketone (PEEK) sonic, PEEK ultrasonic, SS sonic and SS ultrasonic tips. Post‐treatment analyses included stereomicroscopy, vertical scanning interferometry (VSI), scanning electron microscopy (SEM) and energy‐dispersive X‐ray spectroscopy (EDS).

Results

Air‐polishing was associated with a favourable combination of high cleaning efficacy and preserved native surface morphology. SEM and VSI analyses revealed scratching, gouging and material loss on titanium abutments following instrumentation with metallic devices, whereas EPAP preserved surface morphology. Zirconia abutments demonstrated minimal topographical disruption across most modalities; however, surface residues and material smearing were detected following nearly all treatments except EPAP. EDS analyses identified elemental surface transfer on zirconia abutments following instrumentation with stainless‐steel and titanium instruments.

Conclusion

All mechanical instrumentation modalities altered titanium and zirconia surfaces to varying degrees. On titanium, EPAP was associated with a favourable combination of high cleaning efficacy and preserved native surface morphology. On zirconia, both air‐polishing modalities achieved high cleaning efficacy with minimal topographical alteration.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumZirconiumDental AbutmentsDental ImplantsSurface PropertiesMicroscopy, Electron, ScanningIn Vitro TechniquesErythritolSpectrometry, X-Ray EmissionMaterials TestingGlycinePolymersDental PolishingKetonesPolyethylene GlycolsInterferometryStomatitisBenzophenones

Stichwörter der Autor:innen

SEMdental implantserythritolglycineinterferometrymucositissurface roughnesszirconia

Substanzen

TitaniumZirconiumzirconium oxideDental ImplantsErythritolGlycinePolymersKetonesPolyethylene Glycolspolyetheretherketone

Autor:innen und Institutionen

  • Discipline of Periodontics, Sydney Dental School, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia.
  • Epidemiology/Applied Biostatistics, Australian Institute of Health Innovation, Macquarie University, Sydney, Australia.

ORCID-Profile: Tim Badgery-Parker, Tihana Divnić-Resnik

Förderung

  • Sydney Dental School Research Committee (SEED)
  • The University of Sydney Nano Institute (Sydney Nano)
  • Science for Equity, Empowerment and Development Division
  • Nano Institute, University of Sydney

Zitieren

APA

Kamel, M. S., Spahr, A., Badgery-Parker, T., & Divnić-Resnik, T. (2026). Cleaning Efficacy and Surface Alterations of Titanium and Zirconia Implant Abutments Following Mechanical Instrumentation: An In Vitro Study. Clinical Oral Implants Research, 37(11), 1402-1419. https://doi.org/10.1111/clr.70182

Vancouver

Kamel MS, Spahr A, Badgery-Parker T, Divnić-Resnik T. Cleaning Efficacy and Surface Alterations of Titanium and Zirconia Implant Abutments Following Mechanical Instrumentation: An In Vitro Study. Clinical Oral Implants Research. 2026;37(11):1402-1419. doi:10.1111/clr.70182

BibTeX
@article{Kamel2026,
  author = {Kamel, Marina Salah and Spahr, Axel and Badgery-Parker, Tim and Divnić-Resnik, Tihana},
  title = {Cleaning Efficacy and Surface Alterations of Titanium and Zirconia Implant Abutments Following Mechanical Instrumentation: An In Vitro Study},
  journal = {Clinical Oral Implants Research},
  year = {2026},
  volume = {37},
  number = {11},
  pages = {1402--1419},
  doi = {10.1111/clr.70182}
}
Kostenlos starten →