Exploring the effect of chlorhexidine concentration on the biocorrosion behavior of Ti6Al4V for dental implants
Microscopy Research and Technique · 2024-07 · 87 (7) · 1552-1565
DOI: 10.1002/jemt.24538 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microscopy Research and Technique, online erschienen am 02.03.2024. Verfasst von Masoumeh Faramarzi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Periodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran. Hauptthemen laut MEDLINE: Chlorhexidine, Titanium, Alloys, Dental Implants. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Tabriz University of Medical Sciences.
Abstract (Originalsprache)
Corrosion of dental implants is one of the most critical factors in the failure of implant treatments. Generally, corrosion depends on the type of material used in implants and the chemical composition of the oral environment. Due to the antibacterial activities, mouthwashes and chlorhexidine gels are often used after implant surgery. Ti6Al4V is commonly used in manufacturing dental implants. The present study aims to investigate the corrosion behavior of the Ti6Al4V alloy under different concentrations of chlorhexidine (0.12%, 0.2%,and 2%) during 2‐ and 24‐h immersion. This way corrosion may be minimized while obtaining an antibacterial environment around the implant. In this regard, the electrochemical behavior of the specimens was investigated using polarization and impedance tests, and then their morphology, cross‐section and nano‐tribological behavior were evaluated using atomic force microscopy, scanning electron microscopy, energy dispersive x‐ray spectroscopy, and nano‐scratch test. The results show that using chlorhexidine solution with a concentration of 0.12% could yield a lower corrosion rate and material loss after implant surgery. Research Highlights Open circuit potential values increase with immersion time, which suggests multistage passivation of the surface during immersion in chlorhexidine. Specimens in 0.12% chlorhexidine show improved thermodynamic corrosion resistance. Nano‐scratch testing demonstrates higher scratch resistance for specimens in 0.12% chlorhexidine solution after 2‐h immersion. Higher chlorhexidine concentration than 0.12% and longer immersion times decrease the resistance of the formed passive layer.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Periodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran.
- Institut für Werkstoffe, Ruhr-Universität Bochum, Bochum, Germany.
- Institute of Biomedical Engineering, Bogaziçi University, Istanbul, Turkey.
ORCID-Profile: Duygu Ege
Förderung
- Tabriz University of Medical Sciences
Zitieren
APA
Faramarzi, M., Shabgard, S., Khalili, V., & Ege, D. (2024). Exploring the effect of chlorhexidine concentration on the biocorrosion behavior of Ti6Al4V for dental implants. Microscopy Research and Technique, 87(7), 1552-1565. https://doi.org/10.1002/jemt.24538
Vancouver
Faramarzi M, Shabgard S, Khalili V, Ege D. Exploring the effect of chlorhexidine concentration on the biocorrosion behavior of Ti6Al4V for dental implants. Microscopy Research and Technique. 2024;87(7):1552-1565. doi:10.1002/jemt.24538
BibTeX
@article{Faramarzi2024,
author = {Faramarzi, Masoumeh and Shabgard, Sara and Khalili, Vida and Ege, Duygu},
title = {Exploring the effect of chlorhexidine concentration on the biocorrosion behavior of Ti6Al4V for dental implants},
journal = {Microscopy Research and Technique},
year = {2024},
volume = {87},
number = {7},
pages = {1552--1565},
doi = {10.1002/jemt.24538}
}
EUVIMED