Utility of Quantitative 99m Tc-MAA SPECT/CT for 90 yttrium-Labelled Microsphere Treatment Planning: Calculating Vascularized Hepatic Volume and Dosimetric Approach
International Journal of Molecular Imaging · 2011
DOI: 10.1155/2011/398051 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Molecular Imaging, 2011. Verfasst von Etienne Garin und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Comprehensive Cancer Center Eugène Marquis, CS 44229, 35042 Rennes, France. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).
Abstract (Originalsprache)
Objectives
The aim of this study was to assess the effectiveness of SPECT/CT for volume measurements and to report a case illustrating the major impact of SPECT/CT in calculating the vascularized liver volume and dosimetry prior to injecting radiolabelled yttrium-90 microspheres (Therasphere). Materials and Methods . This was a phantom study, involving volume measurements carried out by two operators using SPECT and SPECT/CT images. The percentage of error for each method was calculated, and interobserver reproducibility was evaluated. A treatment using Therasphere was planned in a patient with three hepatic arteries, and the quantitative analysis of SPECT/CT for this patient is provided.
Results
SPECT/CT volume measurements proved to be accurate (mean error
Autor:innen und Institutionen
- Department of Nuclear Medicine, Comprehensive Cancer Center Eugène Marquis, CS 44229, 35042 Rennes, France.
Zitieren
APA
Garin, E., Rolland, Y., Lenoir, L., Pracht, M., Mesbah, H., Porée, P., Laffont, S., Clement, B., Raoul, J. L., & Boucher, E. (2011). Utility of Quantitative 99m Tc-MAA SPECT/CT for 90 yttrium-Labelled Microsphere Treatment Planning: Calculating Vascularized Hepatic Volume and Dosimetric Approach. International Journal of Molecular Imaging. https://doi.org/10.1155/2011/398051
Vancouver
Garin E, Rolland Y, Lenoir L, Pracht M, Mesbah H, Porée P, et al. Utility of Quantitative 99m Tc-MAA SPECT/CT for 90 yttrium-Labelled Microsphere Treatment Planning: Calculating Vascularized Hepatic Volume and Dosimetric Approach. International Journal of Molecular Imaging. 2011. doi:10.1155/2011/398051
BibTeX
@article{Garin2011,
author = {Garin, Etienne and Rolland, Yan and Lenoir, Laurence and Pracht, Marc and Mesbah, Habiba and Porée, Philippe and Laffont, Sophie and Clement, Bruno and Raoul, Jean-Luc and Boucher, Eveline},
title = {Utility of Quantitative 99m Tc-MAA SPECT/CT for 90 yttrium-Labelled Microsphere Treatment Planning: Calculating Vascularized Hepatic Volume and Dosimetric Approach},
journal = {International Journal of Molecular Imaging},
year = {2011},
doi = {10.1155/2011/398051}
}
EUVIMED