EUVIMEDEUVIMED entdecken
Crossref

SPECT and CT misregistration reduction in [99mTc]Tc-MAA SPECT/CT for precision liver radioembolization treatment planning

Zhonglin Lu, Gefei Chen, Han Jiang, Jingzhang Sun, Ko-Han Lin, Greta S P Mok iD

European Journal of Nuclear Medicine and Molecular Imaging · 2023-07 · 50 (8) · 2319-2330

DOI: 10.1007/s00259-023-06149-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, online erschienen am 06.03.2023. Verfasst von Zhonglin Lu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa…. Hauptthemen laut MEDLINE: Embolization, Therapeutic, Liver Neoplasms. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: Fundo para o Desenvolvimento das Ciências e da Tecnologia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Respiration and body movement induce misregistration between static [99mTc]Tc-MAA SPECT and CT, causing lung shunting fraction (LSF) and tumor-to-normal liver ratio (TNR) errors for 90Y radioembolization planning. We aim to alleviate the misregistration between [99mTc]Tc-MAA SPECT and CT using two registration schemes on simulation and clinical data. METHODS: In the simulation study, 70 XCAT phantoms were modeled. The SIMIND Monte Carlo program and OS-EM algorithm were used for projection generation and reconstruction, respectively. Low-dose CT (LDCT) at end-inspiration was simulated for attenuation correction (AC), lungs and liver segmentation, while contrast-enhanced CT (CECT) was simulated for tumor and perfused liver segmentation. In the clinical study, 16 patient data including [99mTc]Tc-MAA SPECT/LDCT and CECT with observed SPECT and CT mismatch were analyzed. Two liver-based registration schemes were studied: SPECT registered to LDCT/CECT and vice versa. Mean count density (MCD) of different volumes-of-interest (VOIs), normalized mutual information (NMI), LSF, TNR, and maximum injected activity (MIA) based on the partition model before and after registration were compared. Wilcoxon signed-rank test was performed. RESULTS: In the simulation study, compared to before registration, registrations significantly reduced estimation errors of MCD of all VOIs, LSF (Scheme 1: - 100.28%, Scheme 2: - 101.59%), and TNR (Scheme 1: - 7.00%, Scheme 2: - 5.67%), as well as MIA (Scheme 1: - 3.22%, Scheme 2: - 2.40%). In the clinical study, Scheme 1 reduced 33.68% LSF and increased 14.75% TNR, while Scheme 2 reduced 38.88% LSF and increased 6.28% TNR compared to before registration. One patient may change from 90Y radioembolization untreatable to treatable and other patients may change the MIA up to 25% after registration. NMI between SPECT and CT was significantly increased after registrations in both studies. CONCLUSION: Registration between static [99mTc]Tc-MAA SPECT and corresponding CTs is feasible to reduce their spatial mismatch and improve dosimetric estimation. The improvement of LSF is larger than TNR. Our method can potentially improve patient selection and personalized treatment planning for liver radioembolization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Embolization, TherapeuticLiver NeoplasmsHumansTomography, Emission-Computed, Single-PhotonSingle Photon Emission Computed Tomography Computed TomographyTechnetium Tc 99m Aggregated AlbuminYttrium RadioisotopesMicrospheresRetrospective Studies

Stichwörter der Autor:innen

RegistrationRespiratory motionSPECT/CT[99mTc]Tc-macroaggregated albumin

Substanzen

Technetium Tc 99m Aggregated AlbuminYttrium Radioisotopes

Autor:innen und Institutionen

  • Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China.
  • Center for Cognitive and Brain Sciences, Institute of Collaborative Innovation, University of Macau, Taipa, Macau SAR, China.
  • Department of Nuclear Medicine, Taipei Veterans General Hospital, Taipei, 11217, Taiwan. khlin3@vghtpe.gov.tw.
  • Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China. gretamok@um.edu.mo.
  • Center for Cognitive and Brain Sciences, Institute of Collaborative Innovation, University of Macau, Taipa, Macau SAR, China. gretamok@um.edu.mo.
  • Ministry of Education Frontiers Science Center for Precision Oncology, Faculty of Health Science, University of Macau, Taipa, Macau SAR, China. gretamok@um.edu.mo.

ORCID-Profile: Greta S P Mok

Förderung

  • Fundo para o Desenvolvimento das Ciências e da Tecnologia

Zitieren

APA

Lu, Z., Chen, G., Jiang, H., Sun, J., Lin, K. H., & Mok, G. S. P. (2023). SPECT and CT misregistration reduction in [99mTc]Tc-MAA SPECT/CT for precision liver radioembolization treatment planning. European Journal of Nuclear Medicine and Molecular Imaging, 50(8), 2319-2330. https://doi.org/10.1007/s00259-023-06149-9

Vancouver

Lu Z, Chen G, Jiang H, Sun J, Lin KH, Mok GSP. SPECT and CT misregistration reduction in [99mTc]Tc-MAA SPECT/CT for precision liver radioembolization treatment planning. European Journal of Nuclear Medicine and Molecular Imaging. 2023;50(8):2319-2330. doi:10.1007/s00259-023-06149-9

BibTeX
@article{Lu2023,
  author = {Lu, Zhonglin and Chen, Gefei and Jiang, Han and Sun, Jingzhang and Lin, Ko-Han and Mok, Greta S P},
  title = {SPECT and CT misregistration reduction in [99mTc]Tc-MAA SPECT/CT for precision liver radioembolization treatment planning},
  journal = {European Journal of Nuclear Medicine and Molecular Imaging},
  year = {2023},
  volume = {50},
  number = {8},
  pages = {2319--2330},
  doi = {10.1007/s00259-023-06149-9}
}
Kostenlos starten →