Deep Learning–Enabled Quantification of 99m Tc-Pyrophosphate SPECT/CT for Cardiac Amyloidosis
Journal of Nuclear Medicine · 2024-07 · 65 (7) · 1144-1150
DOI: 10.2967/jnumed.124.267542 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Nuclear Medicine, online erschienen am 09.05.2024. Verfasst von Robert J H Miller und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Sciences, University of Calgary, Calgary, Alberta, Canada. Hauptthemen laut MEDLINE: Technetium Tc 99m Pyrophosphate, Deep Learning, Single Photon Emission Computed Tomography Computed Tomography. Die Arbeit wurde bisher 41-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS.
Abstract (Originalsprache)
Transthyretin cardiac amyloidosis (ATTR CA) is increasingly recognized as a cause of heart failure in older patients, with 99mTc-pyrophosphate imaging frequently used to establish the diagnosis. Visual interpretation of SPECT images is the gold standard for interpretation but is inherently subjective. Manual quantitation of SPECT myocardial 99mTc-pyrophosphate activity is time-consuming and not performed clinically. We evaluated a deep learning approach for fully automated volumetric quantitation of 99mTc-pyrophosphate using segmentation of coregistered anatomic structures from CT attenuation maps.
Methods
Patients who underwent SPECT/CT 99mTc-pyrophosphate imaging for suspected ATTR CA were included. Diagnosis of ATTR CA was determined using standard criteria. Cardiac chambers and myocardium were segmented from CT attenuation maps using a foundational deep learning model and then applied to attenuation-corrected SPECT images to quantify radiotracer activity. We evaluated the diagnostic accuracy of target-to-background ratio (TBR), cardiac pyrophosphate activity (CPA), and volume of involvement (VOI) using the area under the receiver operating characteristic curve (AUC). We then evaluated associations with the composite outcome of cardiovascular death or heart failure hospitalization.
Results
In total, 299 patients were included (median age, 76 y), with ATTR CA diagnosed in 83 (27.8%) patients. CPA (AUC, 0.989; 95% CI, 0.974-1.00) and VOI (AUC, 0.988; 95% CI, 0.973-1.00) had the highest prediction performance for ATTR CA. The next highest AUC was for TBR (AUC, 0.979; 95% CI, 0.964-0.995). The AUC for CPA was significantly higher than that for heart-to-contralateral ratio (AUC, 0.975; 95% CI, 0.952-0.998; P = 0.046). Twenty-three patients with ATTR CA experienced cardiovascular death or heart failure hospitalization. All methods for establishing TBR, CPA, and VOI were associated with an increased risk of events after adjustment for age, with hazard ratios ranging from 1.41 to 1.84 per SD increase.
Conclusion
Deep learning segmentation of coregistered CT attenuation maps is not affected by the pattern of radiotracer uptake and allows for fully automatic quantification of hot-spot SPECT imaging such as 99mTc-pyrophosphate. This approach can be used to accurately identify patients with ATTR CA and may play a role in risk prediction.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Cardiac Sciences, University of Calgary, Calgary, Alberta, Canada.
- Departments of Medicine (Division of Artificial Intelligence in Medicine), Imaging, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, California; and.
- Signal and Image Processing Institute, Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California.
- Departments of Medicine (Division of Artificial Intelligence in Medicine), Imaging, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, California; and piotr.slomka@cshs.org.
Förderung
- NHLBI NIH HHS
Zitieren
APA
Miller, R. J. H., Shanbhag, A., Michalowska, A. M., Kavanagh, P., Liang, J. X., Builoff, V., Fine, N. M., Dey, D., Berman, D. S., & Slomka, P. J. (2024). Deep Learning–Enabled Quantification of 99m Tc-Pyrophosphate SPECT/CT for Cardiac Amyloidosis. Journal of Nuclear Medicine, 65(7), 1144-1150. https://doi.org/10.2967/jnumed.124.267542
Vancouver
Miller RJH, Shanbhag A, Michalowska AM, Kavanagh P, Liang JX, Builoff V, et al. Deep Learning–Enabled Quantification of 99m Tc-Pyrophosphate SPECT/CT for Cardiac Amyloidosis. Journal of Nuclear Medicine. 2024;65(7):1144-1150. doi:10.2967/jnumed.124.267542
BibTeX
@article{Miller2024,
author = {Miller, Robert J H and Shanbhag, Aakash and Michalowska, Anna M and Kavanagh, Paul and Liang, Joanna X and Builoff, Valerie and Fine, Nowell M and Dey, Damini and Berman, Daniel S and Slomka, Piotr J},
title = {Deep Learning–Enabled Quantification of 99m Tc-Pyrophosphate SPECT/CT for Cardiac Amyloidosis},
journal = {Journal of Nuclear Medicine},
year = {2024},
volume = {65},
number = {7},
pages = {1144--1150},
doi = {10.2967/jnumed.124.267542}
}