EUVIMEDEUVIMED entdecken
Multizentrische Studie

Reproducibility of Lung Densitometry with Photon-counting Detector and Energy-integrating Detector CT: A Multi-Institutional Phantom Study

Saman Sotoudeh-Paima iD, Jim O'Doherty iD, Stephen M Humphries iD, Jarron Atha, Marrissa J McIntosh, Jessica C Sieren iD, Steven T Bache iD, Andres Abadia iD, Juan Carlos Ramirez-Giraldo iD, Raúl San José Estépar iD, Ehsan Samei iD, Eric A Hoffman iD und 3 weitere

Radiology: Cardiothoracic Imaging · 01.12.2026 · 8 (6)

DOI: 10.1148/ryct.250312 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Radiology: Cardiothoracic Imaging, erschienen am 01.12.2026. Verfasst von Saman Sotoudeh-Paima und 14 weiteren Autor:innen. Beteiligte Einrichtung: Center for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University School of Medicine, 2424 Erw…. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Lung, Densitometry. Die Arbeit nennt 44 Literaturangaben. Gefördert von: National Institutes of Health, Siemens Healthineers.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this multi-institutional, multiphantom study, photon-counting detector CT provided more accurate and reproducible lung densitometry while maintaining comparability with energy-integrating detector CT protocols.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedLungDensitometryPhantoms, ImagingReproducibility of ResultsHumansRadiation DosagePhotons

Stichwörter der Autor:innen

CTCT-QuantitativeCT–Photon CountingChronic Obstructive Pulmonary DiseaseComparative StudiesLungPhantom StudiesPhysicsTechnology AssessmentThorax

Autor:innen und Institutionen

  • Center for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University School of Medicine, 2424 Erwin Rd, Hock Plaza, Ste 302, Durham, NC 27705.
  • Department of Electrical & Computer Engineering, Duke University, Durham, NC.
  • NAM CT R&D Collaborations, Siemens Medical Solutions, Malvern, Pa.
  • Department of Radiology, National Jewish Health, Denver, Colo.
  • Department of Radiology, University of Iowa, Iowa City, Iowa.
  • Medical Physics Graduate Program, Duke University, Durham, NC.

ORCID-Profile: Saman Sotoudeh-Paima, Jim O'Doherty, Stephen M Humphries, Jessica C Sieren, Steven T Bache, Andres Abadia, Juan Carlos Ramirez-Giraldo, Raúl San José Estépar, Ehsan Samei, Eric A Hoffman, David A Lynch, Sean B Fain, Ehsan Abadi

Förderung

  • National Institutes of Health
  • Siemens Healthineers

Zitieren

APA

Sotoudeh-Paima, S., O'Doherty, J., Humphries, S. M., Atha, J., McIntosh, M. J., Sieren, J. C., Bache, S. T., Abadia, A., Ramirez-Giraldo, J. C., San José Estépar, R., Samei, E., Hoffman, E. A., Lynch, D. A., Fain, S. B., & Abadi, E. (2026). Reproducibility of Lung Densitometry with Photon-counting Detector and Energy-integrating Detector CT: A Multi-Institutional Phantom Study. Radiology: Cardiothoracic Imaging, 8(6). https://doi.org/10.1148/ryct.250312

Vancouver

Sotoudeh-Paima S, O'Doherty J, Humphries SM, Atha J, McIntosh MJ, Sieren JC, et al. Reproducibility of Lung Densitometry with Photon-counting Detector and Energy-integrating Detector CT: A Multi-Institutional Phantom Study. Radiology: Cardiothoracic Imaging. 2026;8(6). doi:10.1148/ryct.250312

BibTeX
@article{SotoudehPaima2026,
  author = {Sotoudeh-Paima, Saman and O'Doherty, Jim and Humphries, Stephen M and Atha, Jarron and McIntosh, Marrissa J and Sieren, Jessica C and Bache, Steven T and Abadia, Andres and Ramirez-Giraldo, Juan Carlos and San José Estépar, Raúl and Samei, Ehsan and Hoffman, Eric A and Lynch, David A and Fain, Sean B and Abadi, Ehsan},
  title = {Reproducibility of Lung Densitometry with Photon-counting Detector and Energy-integrating Detector CT: A Multi-Institutional Phantom Study},
  journal = {Radiology: Cardiothoracic Imaging},
  year = {2026},
  volume = {8},
  number = {6},
  doi = {10.1148/ryct.250312}
}
Kostenlos starten →