Fetal MRI at 3 T: Principles to Optimize Success
RadioGraphics · 2023-04-01 · 43 (4)
DOI: 10.1148/rg.220141 ↗At a glance
Journal article in RadioGraphics, published on 2023-04-01. Written by Fedel Machado-Rivas and 8 co-authors. Institution: From the Department of Radiology, Boston Children's Hospital, 300 Longwood Ave, Boston, MA 02215 (F.M.R., M.C.C.A., O.A., M.A.B., C.C., M.R., A.G., C…. Major MEDLINE topics: Magnetic Resonance Imaging, Prenatal Diagnosis. Cited 25 times so far (Crossref); 48 references. The full text is freely available in PubMed Central. Funded by: NINDS NIH HHS, NIBIB NIH HHS, NIDCR NIH HHS.
Abstract (original language)
Fetal MRI has emerged as a cornerstone of prenatal imaging, helping to establish the correct diagnosis in pregnancies affected by congenital anomalies. In the past decade, 3 T imaging was introduced as an alternative to increase the signal-to-noise ratio (SNR) of the pulse sequences and improve anatomic detail. However, imaging at a higher field strength is not without challenges. Many artifacts that are barely appreciable at 1.5 T are amplified at 3 T. A systematic approach to imaging at 3 T that incorporates appropriate patient positioning, a thoughtful protocol design, and sequence optimization minimizes the impact of these artifacts and allows radiologists to reap the benefits of the increased SNR. The sequences used are the same at both field strengths and include single-shot T2-weighted, balanced steady-state free-precession, three-dimensional T1-weighted spoiled gradient-echo, and echo-planar imaging. Synergistic use of these acquisitions to sample various tissue contrasts and in various planes provides valuable information about fetal anatomy and pathologic conditions. In the authors' experience, fetal imaging at 3 T outperforms imaging at 1.5 T for most indications when performed under optimal circumstances. The authors condense the cumulative experience of fetal imaging specialists and MRI technologists who practice at a large referral center into a guideline covering all major aspects of fetal MRI at 3 T, from patient preparation to image interpretation. © RSNA, 2023 Quiz questions for this article are available in the supplemental material.
Subjects
MeSH terms (MEDLINE)
Substances
Authors and institutions
- From the Department of Radiology, Boston Children's Hospital, 300 Longwood Ave, Boston, MA 02215 (F.M.R., M.C.C.A., O.A., M.A.B., C.C., M.R., A.G., C.J.); Department of Radiology, Harvard Medical School, Boston, Mass (J…
ORCID profiles: Fedel Machado-Rivas, Maria Camila Cortes-Albornoz, Onur Afacan, Maria Alejandra Bedoya, Camilo Calixto, Ali Gholipour, Camilo Jaimes
Funding
- NINDS NIH HHS
- NIBIB NIH HHS
- NIDCR NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
- National Institute of Neurological Disorders and Stroke
- National Institute of Dental and Craniofacial Research of the National Institutes of Health
- National Institute of Health Office of the Director Award
- McKnight Endowment Fund for Neuroscience
Cite
APA
Machado-Rivas, F., Cortes-Albornoz, M. C., Afacan, O., Bedoya, M. A., Calixto, C., Choi, J. J., Ruggiero, M., Gholipour, A., & Jaimes, C. (2023). Fetal MRI at 3 T: Principles to Optimize Success. RadioGraphics, 43(4). https://doi.org/10.1148/rg.220141
Vancouver
Machado-Rivas F, Cortes-Albornoz MC, Afacan O, Bedoya MA, Calixto C, Choi JJ, et al. Fetal MRI at 3 T: Principles to Optimize Success. RadioGraphics. 2023;43(4). doi:10.1148/rg.220141
BibTeX
@article{MachadoRivas2023,
author = {Machado-Rivas, Fedel and Cortes-Albornoz, Maria Camila and Afacan, Onur and Bedoya, Maria Alejandra and Calixto, Camilo and Choi, Jungwhan John and Ruggiero, Matthew and Gholipour, Ali and Jaimes, Camilo},
title = {Fetal MRI at 3 T: Principles to Optimize Success},
journal = {RadioGraphics},
year = {2023},
volume = {43},
number = {4},
doi = {10.1148/rg.220141}
}
EUVIMED