Peak torque, rate of torque development and average torque of isometric ankle and elbow contractions show excellent test–retest reliability
Hong Kong Physiotherapy Journal · 2019-06 · 39 (01) · 67-76
DOI: 10.1142/s1013702519500069 ↗Kurz gefasst
Fachartikel in der Zeitschrift Hong Kong Physiotherapy Journal, online erschienen am 02.04.2019. Verfasst von Daniel Simpson und 6 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Health & Nutrition Centre (CHANCE) School of Science, Institute of Technology, Sligo, Ireland. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Peak Torque (PT), Rate of Torque Development (RTD) and Average Torque (AT) over a single contraction assess the three components of muscle function during isometric contractions. Surprisingly, AT has never been reported or its reliability confirmed.
Objectives
This study aims to establish protocol reliability for ankle dorsiflexion and elbow extension isometric muscle function (PT, RTD, AT) in healthy participants using the Biodex System 3 Dynamometer.
Methods
Twelve participants (6 male, 6 female, mean age [Formula: see text] years) performed four maximal isometric contractions on two occasions. Intraclass Correlation Coefficient (ICC), Typical Error (TE) and Coefficient of Variation (CV) for PT, RTD and AT were reported.
Results
The ICC for all strength parameters varied from 0.98–0.92. TE for ankle dorsiflexion PT was 1.38[Formula: see text]Nm, RTD 7.43[Formula: see text]Nm/s and AT 1.33[Formula: see text]Nm, CV varied from [Formula: see text] to [Formula: see text]. For elbow extension, TE was 3.36[Formula: see text]Nm for PT, 14.87[Formula: see text]Nm/s for RTD and 3.03[Formula: see text]Nm for AT, CV varied from [Formula: see text] to [Formula: see text].
Conclusion
Maximal isometric ankle dorsiflexion and elbow extension PT, RTD and AT can be evaluated with excellent reliability when following the described protocol. This testing procedure, including the application of AT, can be confidently applied in research, exercise or clinical settings.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Clinical Health & Nutrition Centre (CHANCE) School of Science, Institute of Technology, Sligo, Ireland.
- School of Public Health, Physiotherapy & Sports Science University College Dublin, Ireland.
Zitieren
APA
Simpson, D., Ehrensberger, M., Nulty, C., Regan, J., Broderick, P., Blake, C., & Monaghan, K. (2019). Peak torque, rate of torque development and average torque of isometric ankle and elbow contractions show excellent test–retest reliability. Hong Kong Physiotherapy Journal, 39(01), 67-76. https://doi.org/10.1142/s1013702519500069
Vancouver
Simpson D, Ehrensberger M, Nulty C, Regan J, Broderick P, Blake C, et al. Peak torque, rate of torque development and average torque of isometric ankle and elbow contractions show excellent test–retest reliability. Hong Kong Physiotherapy Journal. 2019;39(01):67-76. doi:10.1142/s1013702519500069
BibTeX
@article{Simpson2019,
author = {Simpson, Daniel and Ehrensberger, Monika and Nulty, Christopher and Regan, Joanne and Broderick, Patrick and Blake, Catherine and Monaghan, Kenneth},
title = {Peak torque, rate of torque development and average torque of isometric ankle and elbow contractions show excellent test–retest reliability},
journal = {Hong Kong Physiotherapy Journal},
year = {2019},
volume = {39},
number = {01},
pages = {67--76},
doi = {10.1142/s1013702519500069}
}
EUVIMED