Fachartikel in der Zeitschrift International Journal of Sports Physical Therapy, online erschienen am 01.02.2025. Verfasst von Moez Glaied und 1 weiteren Autor:innen. Beteiligte Einrichtung: Aspetar Orthopaedic and Sports Medicine Hospital, Doha, Qatar. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background/Purpose The assessment of ankle plantarflexion force is commonly required in athletic performance and clinical rehabilitation settings to assess the integrity of the calf and lower limb musculature. The force generating capacity of the soleus muscle is thought to be important in many aspects of sporting and everyday function. Unfortunately, there are only a few reliable tests describing the assessment of the strength of the soleus muscle, especially in dorsiflexion greater than plantar grade/neutral which mimics ankle joint positions associated with higher ground contact forces. Accordingly, the purpose of this study is to describe the reliability, feasibility, and clinimetrics of a novel test of plantarflexion force in a clinical setting Methods Test-retest reliability of a seated isometric plantar flexion strength test performed a minimum of one day apart (maximum of six) using the maximum value of four trials was investigated using a force plate and custom apparatus in 61 volunteer adults (of varying activity levels (Tegner one to ten). Inter-rater reliability (ICC 2,1 ), Bland-Altman, and minimal detectable change values were estimated. Results Sixty-one subjects were tested (49 male, 12 female, 39.6±12.6 years, 81.1±13.8kg). Excellent test-retest reliability was demonstrated (ICC 2,1 )=0.976 [0.97 to 0.98], p
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Aspetar Orthopaedic and Sports Medicine Hospital, Doha, Qatar.
- Curtin University, Perth, Australia.
Zitieren
APA
Glaied, M., & Whiteley, R. (2025). Excellent Reliability for an Instrumented Test of Ankle Plantarflexion Force. International Journal of Sports Physical Therapy, 20(2). https://doi.org/10.26603/001c.128591
Vancouver
Glaied M, Whiteley R. Excellent Reliability for an Instrumented Test of Ankle Plantarflexion Force. International Journal of Sports Physical Therapy. 2025;20(2). doi:10.26603/001c.128591
BibTeX
@article{Glaied2025,
author = {Glaied, Moez and Whiteley, Rodney},
title = {Excellent Reliability for an Instrumented Test of Ankle Plantarflexion Force},
journal = {International Journal of Sports Physical Therapy},
year = {2025},
volume = {20},
number = {2},
doi = {10.26603/001c.128591}
}