Handheld dynamometry: Validity and reliability of measuring hip joint rate of torque development and peak torque
PLOS ONE · 16.08.2024 · 19 (8) · e0308956
DOI: 10.1371/journal.pone.0308956 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 16.08.2024. Verfasst von Katherine McNabb und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Professions, Faculty of Health and Education, Manchester Metropolitan University, Manchester, United Kingdom. Hauptthemen laut MEDLINE: Torque, Hip Joint, Muscle Strength Dynamometer, Isometric Contraction. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Measuring rate of torque development (RTD) and peak torque (PT) for hip muscle performance presents challenges in clinical practice. This study investigated the construct validity of a handheld dynamometer (HHD) versus an isokinetic dynamometer (IKD), and intra-rater repeated reliability for RTD and PT and their relationship in hip joint movements.
Methods
Thirty healthy individuals (mean age = 30 ± 8 years, 13 males) underwent two test sessions in a single day. RTD (0–50, 0–100, 0–150, 0-200ms) and PT normalised to body mass in maximal voluntary isometric contractions were measured using a HHD and an IKD in hip flexion, extension, abduction, adduction, internal and external rotation.
Results
For validity between the devices, RTD 0-50 exhibited the largest significant systematic bias in all hip movements (3.41–11.99 Nm·s -1 kg -1 ) and widest limits-of-agreement, while RTD 0-200 had the lowest bias (-1.33–3.99 Nm·s -1 kg -1 ) and narrowest limits-of-agreement. For PT, agreement between dynamometers was observed for hip flexion (0.08 Nm·kg -1 ), abduction (-0.09 Nm·kg -1 ), internal (-0.01 Nm·kg -1 ), and external rotation (0.05 Nm·kg -1 ). For reliability, intra-rater intraclass correlation coefficient (ICC 2,1 ) ranged from moderate to good in RTD 0-50 and RTD 0-100 (0.5–0.88), and good to excellent in RTD 0-150 and RTD 0-200 (0.87–0.95) in all movements. The HHD displayed excellent intra-rater, relative reliability values (ICC 2,1 ) in all movements (0.85–0.95). Pearson’s correlation revealed good linear correlation between PT and RTD 0-150 and RTD 0-200 in all movements ( r = .7 to .87, p = < .001).
Conclusion
Validity analysis demonstrated significant systematic bias and lack of agreement in RTD measures between the HHD and IKD. However, the HHD displays excellent to moderate intra-rater, relative reliability for RTD and PT measures in hip movements. Clinicians may use the HHD for hip muscle PT assessment but note, late phase RTD measures are more reliable, valid, and relate to PT than early phase RTD. Additionally, the correlation between RTD and PT at various time epochs was examined to better understand the relationship between these measures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Health Professions, Faculty of Health and Education, Manchester Metropolitan University, Manchester, United Kingdom.
- Department of Life Sciences, Faculty of Science and Engineering, Manchester Metropolitan University, Manchester, United Kingdom.
- Lancaster Medical School, Faculty of Health and Medicine, Lancaster University, Lancaster, United Kingdom.
- Centre for Musculoskeletal Research, Manchester Academic Health Sciences Centre, University of Manchester, Manchester, United Kingdom.
- Department of Physiotherapy, Manchester University Hospitals NHS Foundation Trust, Manchester, United Kingdom.
ORCID-Profile: Katherine McNabb, María B Sánchez, Neil D Reeves
Zitieren
APA
McNabb, K., Sánchez, M. B., Selfe, J., Reeves, N. D., & Callaghan, M. (2024). Handheld dynamometry: Validity and reliability of measuring hip joint rate of torque development and peak torque. PLOS ONE, 19(8), e0308956. https://doi.org/10.1371/journal.pone.0308956
Vancouver
McNabb K, Sánchez MB, Selfe J, Reeves ND, Callaghan M. Handheld dynamometry: Validity and reliability of measuring hip joint rate of torque development and peak torque. PLOS ONE. 2024;19(8):e0308956. doi:10.1371/journal.pone.0308956
BibTeX
@article{McNabb2024,
author = {McNabb, Katherine and Sánchez, María B and Selfe, James and Reeves, Neil D and Callaghan, Michael},
title = {Handheld dynamometry: Validity and reliability of measuring hip joint rate of torque development and peak torque},
journal = {PLOS ONE},
year = {2024},
volume = {19},
number = {8},
pages = {e0308956},
doi = {10.1371/journal.pone.0308956}
}