EUVIMEDOpdag EUVIMED
Open access

Pulseometry: A differential readout to compensate signal drift of potentiometric probes

Yaotian Wu iD, Junyu Zhou, Yu Qin, Eric Bakker iD

Science Advances · 2026-08-21 · 12 (34)

DOI: 10.1126/sciadv.aef5993 ↗

At a glance

Journal article in Science Advances, published on 2026-08-21. Written by Yaotian Wu and 3 co-authors. Institution: Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland. Major MEDLINE topics: Electrolytes, Ion-Selective Electrodes. 41 references. The full text is freely available in PubMed Central. Funded by: Swiss National Foundation.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Ion selective electrodes are widely used sensors in point-of-care testing devices to assay electrolytes in whole blood samples. With single-use system, the first solution contact normally results in an important signal drift that negatively affects measurement accuracy. In this work, we propose an approach coined pulseometry to compensate for signal drift. The potentiometric signal is processed through a differential circuit incorporating RC components of different time constants. The differential potential will remain constant for a slowly drifting baseline, while a rapid potential change will result in a peak-shaped difference signal that may be baseline subtracted and integrated to extract the components information. The method was successfully integrated into mass fabricated, microfluidic test cards used in commercial blood gas electrolyte analyzers. Blood calcium levels from three individuals were measured, giving SDs of 0.008 to 0.024 mM, improving precision by 36 to 67% compared to potentiometry. These results showcase the potential of pulseometry for improving the performance of electrochemical sensing in clinical diagnostics.

Subjects

MeSH terms (MEDLINE)

ElectrolytesIon-Selective ElectrodesHumansCalciumPotentiometry

Substances

CalciumElectrolytes

Authors and institutions

  • Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland.
  • Eaglenos Sciences Inc., B2-2, Treehouse Headquarters Cluster, No. 73 Tanmi Road, Nanjing Jiangbei New Area, Nanjing, Jiangsu 210044, China.

ORCID profiles: Yaotian Wu, Eric Bakker

Funding

  • Swiss National Foundation

Cite

APA

Wu, Y., Zhou, J., Qin, Y., & Bakker, E. (2026). Pulseometry: A differential readout to compensate signal drift of potentiometric probes. Science Advances, 12(34). https://doi.org/10.1126/sciadv.aef5993

Vancouver

Wu Y, Zhou J, Qin Y, Bakker E. Pulseometry: A differential readout to compensate signal drift of potentiometric probes. Science Advances. 2026;12(34). doi:10.1126/sciadv.aef5993

BibTeX
@article{Wu2026,
  author = {Wu, Yaotian and Zhou, Junyu and Qin, Yu and Bakker, Eric},
  title = {Pulseometry: A differential readout to compensate signal drift of potentiometric probes},
  journal = {Science Advances},
  year = {2026},
  volume = {12},
  number = {34},
  doi = {10.1126/sciadv.aef5993}
}
Start for free →