Polymeric Membrane Potentiometric Ion Sensors with Dual Biocompatible Functionality
Analytical Chemistry · 2025
DOI: 10.1021/acs.analchem.5c04116 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2025. Verfasst von Zhe Liu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Shandong Key Laboratory of Coastal Environmental Processes, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, Shandong …. Hauptthemen laut MEDLINE: Biocompatible Materials, Calcium, Membranes, Artificial, Polymers. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 62 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Taishan Scholar Project of Shandong Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
Polymeric membrane ion-selective electrodes (ISEs) have been routinely used to detect clinically important ions in physiological samples. However, the development of biocompatible potentiometric ion sensors for long-term measurements remains a significant challenge. Herein, a polymeric membrane Ca2+-ISE with dual biocompatible functionality (i.e., antibiofouling and low-cytotoxicity properties) is proposed. It is based on a semifluorinated, plasticizer-free sensing membrane with an immobilized ionophore. A new semifluorinated copolymer, 1H,1H,2H,2H-perfluorooctyl methacrylate-lauryl methacrylate (PFMA-LMA), has been synthesized. The low surface energy of the semifluorinated membrane could effectively prevent the surface adsorption of foulants such as lipids, proteins, and blood cells from biological samples. The immobilization of the sensing component and the plasticizer-free approach could significantly reduce the physiological toxicity of the sensor. Compared to the conventional plasticized poly(vinyl chloride) (PVC)-based membrane Ca2+-ISE, the bifunctional, biocompatible PFMA-LMA membrane electrode exhibits significantly reduced blood cell adhesion and cytotoxicity. The present sensor could be used for continuous real-time monitoring of Ca2+ in human blood for at least 3 days. The proposed strategy of dual biocompatible functionality has promising potential for the development of implantable and wearable polymeric membrane-based electrochemical and optical sensors.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Shandong Key Laboratory of Coastal Environmental Processes, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, Shandong 264003, P. R. China.
- University of the Chinese Academy of Sciences, Beijing 100049, P. R. China.
- B&E Bio-Technology Co. Ltd., Yantai, Shandong 264003, P. R. China.
- School of Pharmacy, Binzhou Medical University, Yantai, Shandong 264003, P. R. China.
- Laboratory for Marine Biology and Biotechnology, Qingdao Marine Science and Technology Center, Qingdao, Shandong 266237, P. R. China.
- Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, Shandong 266071, P. R. China.
ORCID-Profile: Rongning Liang, Wei Qin
Förderung
- National Key Research and Development Program of China
- Taishan Scholar Project of Shandong Province
- National Natural Science Foundation of China
- Key Technology Research and Development Program of Shandong Province
- Centre for Ocean Mega-Research of Science, Chinese Academy of Sciences
- Special Supporting Project of Yantai
Zitieren
APA
Liu, Z., Wang, P., Zhao, H., Liu, A., Liang, R., & Qin, W. (2025). Polymeric Membrane Potentiometric Ion Sensors with Dual Biocompatible Functionality. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c04116
Vancouver
Liu Z, Wang P, Zhao H, Liu A, Liang R, Qin W. Polymeric Membrane Potentiometric Ion Sensors with Dual Biocompatible Functionality. Analytical Chemistry. 2025. doi:10.1021/acs.analchem.5c04116
BibTeX
@article{Liu2025,
author = {Liu, Zhe and Wang, Peng and Zhao, Haijie and Liu, Aohua and Liang, Rongning and Qin, Wei},
title = {Polymeric Membrane Potentiometric Ion Sensors with Dual Biocompatible Functionality},
journal = {Analytical Chemistry},
year = {2025},
doi = {10.1021/acs.analchem.5c04116}
}
EUVIMED