Pulseometry: A differential readout to compensate signal drift of potentiometric probes
Science Advances · 21.08.2026 · 12 (34)
DOI: 10.1126/sciadv.aef5993 ↗Kurz gefasst
Fachartikel in der Zeitschrift Science Advances, erschienen am 21.08.2026. Verfasst von Yaotian Wu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland. Hauptthemen laut MEDLINE: Electrolytes, Ion-Selective Electrodes. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Swiss National Foundation.
Abstract (Originalsprache)
Ion selective electrodes are widely used sensors in point-of-care testing devices to assay electrolytes in whole blood samples. With single-use system, the first solution contact normally results in an important signal drift that negatively affects measurement accuracy. In this work, we propose an approach coined pulseometry to compensate for signal drift. The potentiometric signal is processed through a differential circuit incorporating RC components of different time constants. The differential potential will remain constant for a slowly drifting baseline, while a rapid potential change will result in a peak-shaped difference signal that may be baseline subtracted and integrated to extract the components information. The method was successfully integrated into mass fabricated, microfluidic test cards used in commercial blood gas electrolyte analyzers. Blood calcium levels from three individuals were measured, giving SDs of 0.008 to 0.024 mM, improving precision by 36 to 67% compared to potentiometry. These results showcase the potential of pulseometry for improving the performance of electrochemical sensing in clinical diagnostics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland.
- Eaglenos Sciences Inc., B2-2, Treehouse Headquarters Cluster, No. 73 Tanmi Road, Nanjing Jiangbei New Area, Nanjing, Jiangsu 210044, China.
ORCID-Profile: Yaotian Wu, Eric Bakker
Förderung
- Swiss National Foundation
Zitieren
APA
Wu, Y., Zhou, J., Qin, Y., & Bakker, E. (2026). Pulseometry: A differential readout to compensate signal drift of potentiometric probes. Science Advances, 12(34). https://doi.org/10.1126/sciadv.aef5993
Vancouver
Wu Y, Zhou J, Qin Y, Bakker E. Pulseometry: A differential readout to compensate signal drift of potentiometric probes. Science Advances. 2026;12(34). doi:10.1126/sciadv.aef5993
BibTeX
@article{Wu2026,
author = {Wu, Yaotian and Zhou, Junyu and Qin, Yu and Bakker, Eric},
title = {Pulseometry: A differential readout to compensate signal drift of potentiometric probes},
journal = {Science Advances},
year = {2026},
volume = {12},
number = {34},
doi = {10.1126/sciadv.aef5993}
}
EUVIMED