EUVIMEDEUVIMED entdecken
Open Access

Augmenting ultrasound for continuous glucose monitoring via a wearable acoustically readable microneedle patch

Wanglinhan Zhang iD, Jiangang Xu iD, Xinjia Li iD, Yeji Jang iD, Qiqi Liu, Weixin Ma iD, Guojie Luo iD, Ming Ma, Qingqing Wang iD, Yi He iD, Qi Yuan iD, Jae-Woong Jeong iD und 2 weitere

Science Advances · 2026

DOI: 10.1126/sciadv.aec3209 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Science Advances, 2026. Verfasst von Wanglinhan Zhang und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong Special Administrative Region. Hauptthemen laut MEDLINE: Continuous Glucose Monitoring, Ultrasonics. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 82 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Natural Science Foundation of China, National Research Foundation of Korea, NSFC/RGC Joint Research Scheme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Continuous glucose monitoring (CGM) represents substantial advancement, yet poses a challenge in wearable health care development. Current enzymatic CGM faces limitations in stability, cost, and durability. We introduce an enzyme-free, wearable acoustically readable microneedle patch (ARMPatch) composed of glucose-responsive hydrogel. Positioned between a standard ultrasound probe and the skin, ARMPatch acts as an acoustic interface enabling CGM using conventional ultrasound. Its hydrogel microneedles minimally penetrate the epidermis, allowing interstitial fluid to trigger variable swelling of the microneedles in response to glucose fluctuations. ARMPatch delivers stable and selective glucose readings for up to 56 days. Glucose variations with millimolar resolution are obtained via ultrasound within a response time of 30 to 60 minutes. In vivo CGM in animal models for 7 days reveals a reversible correlation between microneedle swelling and glucose variations. Acting as “accessory” for standard ultrasound probes, this approach offers a minimally invasive, cost-effective, and long-lasting solution to non-enzymatic CGM, expanding the utility of ultrasound in wearable biosensing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Continuous Glucose MonitoringUltrasonicsHydrogelsAnimalsExtracellular FluidMaleMiceMice, NudeGlucoseAcoustics

Substanzen

HydrogelsGlucose

Autor:innen und Institutionen

  • Department of Mechanical Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong Special Administrative Region.
  • School of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea.
  • State Key Laboratory of Biomedical Imaging Science and System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
  • Department of Medical Ultrasonics, The Eighth Affiliated Hospital of Sun Yat-sen University, Shenzhen 518033, China.

ORCID-Profile: Wanglinhan Zhang, Jiangang Xu, Xinjia Li, Yeji Jang, Weixin Ma, Guojie Luo, Qingqing Wang, Yi He, Qi Yuan, Jae-Woong Jeong, Long Meng, Zhongqing Su

Förderung

  • National Natural Science Foundation of China
  • National Research Foundation of Korea
  • NSFC/RGC Joint Research Scheme
  • Hong Kong RGC Project

Zitieren

APA

Zhang, W., Xu, J., Li, X., Jang, Y., Liu, Q., Ma, W., Luo, G., Ma, M., Wang, Q., He, Y., Yuan, Q., Jeong, J. W., Meng, L., & Su, Z. (2026). Augmenting ultrasound for continuous glucose monitoring via a wearable acoustically readable microneedle patch. Science Advances. https://doi.org/10.1126/sciadv.aec3209

Vancouver

Zhang W, Xu J, Li X, Jang Y, Liu Q, Ma W, et al. Augmenting ultrasound for continuous glucose monitoring via a wearable acoustically readable microneedle patch. Science Advances. 2026. doi:10.1126/sciadv.aec3209

BibTeX
@article{Zhang2026,
  author = {Zhang, Wanglinhan and Xu, Jiangang and Li, Xinjia and Jang, Yeji and Liu, Qiqi and Ma, Weixin and Luo, Guojie and Ma, Ming and Wang, Qingqing and He, Yi and Yuan, Qi and Jeong, Jae-Woong and Meng, Long and Su, Zhongqing},
  title = {Augmenting ultrasound for continuous glucose monitoring via a wearable acoustically readable microneedle patch},
  journal = {Science Advances},
  year = {2026},
  doi = {10.1126/sciadv.aec3209}
}
Kostenlos starten →