Continuous Glucose Monitoring (CGM) in Sports—A Comparison between a CGM Device and Lab-Based Glucose Analyser under Resting and Exercising Conditions in Athletes
International Journal of Environmental Research and Public Health · 25.07.2023 · 20 (15) · 6440
DOI: 10.3390/ijerph20156440 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift International Journal of Environmental Research and Public Health, online erschienen am 25.07.2023. Verfasst von Helen Bauhaus und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biochemistry, German Sport University Cologne, 50933 Cologne, Germany. Hauptthemen laut MEDLINE: Blood Glucose, Exercise, Blood Glucose Self-Monitoring. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The objective of this pilot study was to compare glucose concentrations in capillary blood (CB) samples analysed in a laboratory by a validated method and glucose concentrations measured in the interstitial fluid (ISF) by continuous glucose monitoring (CGM) under different physical activity levels in a postprandial state in healthy athletes without diabetes. As a physiological shift occurs between glucose concentration from the CB into the ISF, the applicability of CGM in sports, especially during exercise, as well as the comparability of CB and ISF data necessitate an in-depth assessment. Ten subjects (26 ± 4 years, 67 ± 11 kg bodyweight (BW), 11 ± 3 h) were included in the study. Within 14 days, they underwent six tests consisting of (a) two tests resting fasted (HC_Rest/Fast and LC_Rest/Fast), (b) two tests resting with intake of 1 g glucose/kg BW (HC_Rest/Glc and LC_Rest/Glc), (c) running for 60 min at moderate (ModExerc/Glc), and (d) high intensity after intake of 1 g glucose/kg BW (IntExerc/Glc). Data were collected in the morning, following a standardised dinner before test day. Sensor-based glucose concentrations were compared to those determined from capillary blood samples collected at the time of sensor-based analyses and subjected to laboratory glucose measurements. Pearson’s r correlation coefficient was highest for Rest/Glc (0.92, p < 0.001) compared to Rest/Fast (0.45, p < 0.001), ModExerc/Glc (0.60, p < 0.001) and IntExerc/Glc (0.70, p < 0.001). Mean absolute relative deviation (MARD) and standard deviation (SD) was smallest for resting fasted and similar between all other conditions (Rest/Fast: 8 ± 6%, Rest/Glc: 17 ± 12%, ModExerc/Glc: 22 ± 24%, IntExerc/Glc: 18 ± 17%). However, Bland–Altman plot analysis showed a higher range between lower and upper limits of agreement (95% confidence interval) of paired data under exercising compared to resting conditions. Under resting fasted conditions, both methods produce similar outcomes. Under resting postprandial and exercising conditions, respectively, there are differences between both methods. Based on the results of this study, the application of CGM in healthy athletes is not recommended without concomitant nutritional or medical advice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Biochemistry, German Sport University Cologne, 50933 Cologne, Germany.
- German Research Centre of Elite Sports, German Sport University Cologne, 50933 Cologne, Germany.
- Manfred Donike Institute for Doping Analysis, 50933 Cologne, Germany.
- Centre for Preventive Doping Research, German Sport University Cologne, 50933 Cologne, Germany.
ORCID-Profile: Helen Bauhaus
Zitieren
APA
Bauhaus, H., Erdogan, P., Braun, H., & Thevis, M. (2023). Continuous Glucose Monitoring (CGM) in Sports—A Comparison between a CGM Device and Lab-Based Glucose Analyser under Resting and Exercising Conditions in Athletes. International Journal of Environmental Research and Public Health, 20(15), 6440. https://doi.org/10.3390/ijerph20156440
Vancouver
Bauhaus H, Erdogan P, Braun H, Thevis M. Continuous Glucose Monitoring (CGM) in Sports—A Comparison between a CGM Device and Lab-Based Glucose Analyser under Resting and Exercising Conditions in Athletes. International Journal of Environmental Research and Public Health. 2023;20(15):6440. doi:10.3390/ijerph20156440
BibTeX
@article{Bauhaus2023,
author = {Bauhaus, Helen and Erdogan, Pinar and Braun, Hans and Thevis, Mario},
title = {Continuous Glucose Monitoring (CGM) in Sports—A Comparison between a CGM Device and Lab-Based Glucose Analyser under Resting and Exercising Conditions in Athletes},
journal = {International Journal of Environmental Research and Public Health},
year = {2023},
volume = {20},
number = {15},
pages = {6440},
doi = {10.3390/ijerph20156440}
}
EUVIMED