EUVIMEDSkopri EUVIMED
Open access

176 Lu + clock comparison at the 10 −18 level via correlation spectroscopy

Zhang Zhiqiang iD, Kyle J Arnold iD, Rattakorn Kaewuam iD, Murray D Barrett iD

Science Advances · 2023-05-05 · 9 (18)

DOI: 10.1126/sciadv.adg1971 ↗

At a glance

Journal article in Science Advances, published on 2023-05-05. Written by Zhang Zhiqiang and 3 co-authors. Institution: Centre for Quantum Technologies, 3 Science Drive 2, Singapore 117543, Singapore. Cited 66 times so far (Crossref); 45 references. The full text is freely available in PubMed Central.

AstrattDettalji biblijografiċiCiteRelated studies

Abstract (original language)

The extreme precision of optical atomic clocks has led to an anticipated redefinition of the second by the International System of Units. Furthermore, accuracies pushing the boundary of 1 part in 10 18 and beyond will enable new applications, such as in geodesy and tests of fundamental physics. The 1 S 0 to 3 D 1 optical transition in 176 Lu + has exceptionally low sensitivity to external perturbations, making it suitable for practical clock implementations with inaccuracy at or below 10 −18 . Here, we perform high-accuracy comparisons between two 176 Lu + references using correlation spectroscopy. A comparison at different magnetic fields is used to obtain a quadratic Zeeman coefficient of −4.89264(88) Hz/mT for the reference frequency. With a subsequent comparison at low field, we demonstrate agreement at the low 10 −18 level, statistically limited by the averaging time of 42 hours. The evaluated uncertainty in the frequency difference is 9 × 10 −19 and the lowest reported in comparing independent optical references.

Authors and institutions

  • Centre for Quantum Technologies, 3 Science Drive 2, Singapore 117543, Singapore.
  • Temasek Laboratories, National University of Singapore, 5A Engineering Drive 1, Singapore 117411, Singapore.
  • National Institute of Metrology, 3 4 Khlong Ha, Khlong Luang District, Pathum Thani 12120, Thailand.
  • Department of Physics, National University of Singapore, 2 Science Drive 3, Singapore 117551, Singapore.
  • National Metrology Center, 8 Cleantech Loop, 01-20, Singapore 637145, Singapore.

ORCID profiles: Zhang Zhiqiang, Kyle J Arnold, Rattakorn Kaewuam, Murray D Barrett

Cite

APA

Zhiqiang, Z., Arnold, K. J., Kaewuam, R., & Barrett, M. D. (2023). 176 Lu + clock comparison at the 10 −18 level via correlation spectroscopy. Science Advances, 9(18). https://doi.org/10.1126/sciadv.adg1971

Vancouver

Zhiqiang Z, Arnold KJ, Kaewuam R, Barrett MD. 176 Lu + clock comparison at the 10 −18 level via correlation spectroscopy. Science Advances. 2023;9(18). doi:10.1126/sciadv.adg1971

BibTeX
@article{Zhiqiang2023,
  author = {Zhiqiang, Zhang and Arnold, Kyle J and Kaewuam, Rattakorn and Barrett, Murray D},
  title = {176 Lu + clock comparison at the 10 −18 level via correlation spectroscopy},
  journal = {Science Advances},
  year = {2023},
  volume = {9},
  number = {18},
  doi = {10.1126/sciadv.adg1971}
}
Start for free →