Ytterbium lattice clock with systematic uncertainty of 1.3 × 10 −18 and instability at the 10 −19 level
Metrologia · 01.12.2026 · 63 (6) · 065002
DOI: 10.1088/1681-7575/aeb809 ↗Kurz gefasst
Fachartikel in der Zeitschrift Metrologia, online erschienen am 05.11.2026. Verfasst von Qiang Zhu und 10 weiteren Autor:innen. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Chinese Academy of Sciences, National Natural Science Foundation of China, National Science and Technology Major Project.
Abstract (Originalsprache)
We report an optical lattice clock based on 171 Yb atoms with a total systematic uncertainty of 1.3 × 10 − 18 . An in-vacuum buildup cavity was employed to enhance the lattice light power. Differential frequency measurement between two identical clocks facilitates the evaluation of systematic shifts. Synchronous comparison of the two clocks reached a stability level of 2.7 × 10 − 19 in an averaging time of 216 000 s. The blackbody radiation (BBR) shield which is placed in vacuum provides a well-characterized BBR environment, enabling an uncertainty contribution of 8.7 × 10 − 19 from the BBR Stark shift. Lattice light shifts were measured at different lattice depths U , and fitted with a fourth-order polynomial of U . The zero-linear-shift frequency ν zero was determined to be 394 798 260.6(3) MHz. The lattice light shift can be controlled at an uncertainty level of 6.3 × 10 − 19 under typical operating conditions. Other systematic shifts have also been evaluated. The two clocks will be used for remote frequency comparisons between Shanghai and Wuhan.
Förderung
- Chinese Academy of Sciences
- National Natural Science Foundation of China
- National Science and Technology Major Project
- Ministry of Science and Technology of the People’s Republic of China
Zitieren
APA
Zhu, Q., Shi, J., Zhang, Y., Xu, X., Wang, B., Xiong, D., Xiong, Z., Fang, P., Chen, Q., He, L., & Lyu, B. (2026). Ytterbium lattice clock with systematic uncertainty of 1.3 × 10 −18 and instability at the 10 −19 level. Metrologia, 63(6), 065002. https://doi.org/10.1088/1681-7575/aeb809
Vancouver
Zhu Q, Shi J, Zhang Y, Xu X, Wang B, Xiong D, et al. Ytterbium lattice clock with systematic uncertainty of 1.3 × 10 −18 and instability at the 10 −19 level. Metrologia. 2026;63(6):065002. doi:10.1088/1681-7575/aeb809
BibTeX
@article{Zhu2026,
author = {Zhu, Qiang and Shi, Jingran and Zhang, Yuechen and Xu, Xiatian and Wang, Bing and Xiong, Dezhi and Xiong, Zhuanxian and Fang, Pengcheng and Chen, Qunfeng and He, Lingxiang and Lyu, Baolong},
title = {Ytterbium lattice clock with systematic uncertainty of 1.3 × 10 −18 and instability at the 10 −19 level},
journal = {Metrologia},
year = {2026},
volume = {63},
number = {6},
pages = {065002},
doi = {10.1088/1681-7575/aeb809}
}
EUVIMED