Flight-Time Method Modified: Development of a Novel and More Accurate Method for Measuring Vertical Jump Height Using a Smartphone Application
International Journal of Sports Physiology and Performance · 2025
DOI: 10.1123/ijspp.2024-0063 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Sports Physiology and Performance, 2025. Verfasst von Takuya Nishioka und 2 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Physical Education, Keio University, Yokohama, Japan. Hauptthemen laut MEDLINE: Smartphone, Mobile Applications. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
The flight-time method (FT) is used for measuring vertical jump height (JH) in the field because of its convenience; however, FT overestimates JH when the lower limb is flexed at landing. Herein, we proposed a new method (ie, flight-time method modified [FTM]) to address the problem of FT and evaluate its validity and reliability.
Methods
A total of 24 men performed 6 countermovement jumps on force plates (sampling rate: 1000 Hz) while being recorded with a smartphone high-speed camera at 240 frames·s –1 . JH was calculated by the impulse–momentum method (IM), FT, and FTM. For FTM, the flight time and JH were calculated based on the displacement of the greater-trochanter marker using a smartphone application.
Results
JH calculated using FT was significantly higher ( P < .001) compared with JH calculated by IM; however, JH calculated by FTM showed no significant difference with JH calculated by IM. Furthermore, JH calculated by FTM, compared with JH calculated by FT ( ρ = .882; 95% CI, .838–.914), exhibited a stronger, nearly perfect, and significantly positive correlation ( ρ = .987; 95% CI, .982–.991) with JH calculated by IM and showed high reliability.
Conclusions
The FTM proposed in this study had higher concurrent validity compared with FT and a high reliability for measuring countermovement JH because it was not affected by lower-extremity flexion at landing. Therefore, practitioners should consider using FTM as a convenient, low-cost, reliable, and more valid method for measuring JH in the field.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Physical Education, Keio University, Yokohama, Japan.
ORCID-Profile: Takuya Nishioka, Shota Yamaguchi, Takayuki Inami
Zitieren
APA
Nishioka, T., Yamaguchi, S., & Inami, T. (2025). Flight-Time Method Modified: Development of a Novel and More Accurate Method for Measuring Vertical Jump Height Using a Smartphone Application. International Journal of Sports Physiology and Performance. https://doi.org/10.1123/ijspp.2024-0063
Vancouver
Nishioka T, Yamaguchi S, Inami T. Flight-Time Method Modified: Development of a Novel and More Accurate Method for Measuring Vertical Jump Height Using a Smartphone Application. International Journal of Sports Physiology and Performance. 2025. doi:10.1123/ijspp.2024-0063
BibTeX
@article{Nishioka2025,
author = {Nishioka, Takuya and Yamaguchi, Shota and Inami, Takayuki},
title = {Flight-Time Method Modified: Development of a Novel and More Accurate Method for Measuring Vertical Jump Height Using a Smartphone Application},
journal = {International Journal of Sports Physiology and Performance},
year = {2025},
doi = {10.1123/ijspp.2024-0063}
}
EUVIMED