Agreement, Relationships, and Reliability of Measures Obtained From the Drop Jump, Countermovement Rebound Jump, and 10/5 Repeated Jump Tests
International Journal of Sports Physiology and Performance · 2026
DOI: 10.1123/ijspp.2025-0293 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Sports Physiology and Performance, 2026. Verfasst von Rebecca J Eadie und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Behavioural and Health Sciences, Melbourne, VIC, Australia. Hauptthemen laut MEDLINE: Muscle Strength, Exercise Test, Plyometric Exercise. Die Arbeit nennt 62 Literaturangaben.
Abstract (Originalsprache)
Purpose
To investigate the validity of reactive strength index (RSI), reactive strength ratio, and vertical stiffness (K vert ) from the countermovement rebound jump and 10/5 repeated jump test against these metrics from the drop jump. We also investigated relationships between RSI, reactive strength ratio, K vert , and flight time to contraction time within and between protocols. Differences in variables and mechanical components in each jump and reliability of all measures were calculated.
Methods
Twenty-six subjects (18 males, 8 females; age [range]: 20.17 [18.25–31.16] years, weight: 82.20 [64.90–110.30] kg) performed 2 sessions 7 days apart, each consisting of 2 trials of drop jump, countermovement rebound jump, and 10/5 repeated jump test. Bland–Altman limits of agreement were calculated to assess validity. Relationships between outcome metrics (eg, RSI) from different jump types were assessed using Pearson correlations. Differences between variables (eg, flight time) and mechanical components (eg, impulse) from different protocols were assessed using linear mixed models (Cohen d ). Between-session reliability was determined as coefficient of variation and intraclass correlation coefficient.
Results
Relationships between protocols for K vert and RSI/reactive strength ratio were very weak to moderate ( r = .11–.58), and ground contact time differed between protocols ( d = 0.51–1.26). All variables demonstrated moderate to excellent reliability (coefficient of variation: 3.01–17.19%; intraclass correlation coefficient: .59–.97).
Conclusions
Each outcome metric provides unique information, and differences in variables and mechanical components between protocols suggest distinct movement strategies. Protocols should not be used interchangeably.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Behavioural and Health Sciences, Melbourne, VIC, Australia.
- Sports Performance, Recovery, Injury and New Technologies (SPRINT) Research Centre, Australian Catholic University, Melbourne, VIC, Australia.
- Queensland Cricket, Brisbane, QLD, Australia.
ORCID-Profile: Rebecca J Eadie, Paul J Tofari, Stuart J Cormack
Zitieren
APA
Eadie, R. J., Tofari, P. J., Chapman, P., & Cormack, S. J. (2026). Agreement, Relationships, and Reliability of Measures Obtained From the Drop Jump, Countermovement Rebound Jump, and 10/5 Repeated Jump Tests. International Journal of Sports Physiology and Performance. https://doi.org/10.1123/ijspp.2025-0293
Vancouver
Eadie RJ, Tofari PJ, Chapman P, Cormack SJ. Agreement, Relationships, and Reliability of Measures Obtained From the Drop Jump, Countermovement Rebound Jump, and 10/5 Repeated Jump Tests. International Journal of Sports Physiology and Performance. 2026. doi:10.1123/ijspp.2025-0293
BibTeX
@article{Eadie2026,
author = {Eadie, Rebecca J and Tofari, Paul J and Chapman, Paul and Cormack, Stuart J},
title = {Agreement, Relationships, and Reliability of Measures Obtained From the Drop Jump, Countermovement Rebound Jump, and 10/5 Repeated Jump Tests},
journal = {International Journal of Sports Physiology and Performance},
year = {2026},
doi = {10.1123/ijspp.2025-0293}
}
EUVIMED