Fachartikel in der Zeitschrift Journal of Sport Rehabilitation, 2023. Verfasst von Varmeet Kaur und 2 weiteren Autor:innen. Beteiligte Einrichtung: Indian Spinal Injuries Centre, Institute of Rehabilitation Sciences, New Delhi, India. Hauptthemen laut MEDLINE: Mobile Applications, Shoulder Joint. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Context

Clinical assessment of scapular motion is obscured by a lack of clinically accessible and feasible angular measurement tools. This study evaluates the reliability and validity of the smartphone “Clinometer” app in measuring scapular upward rotation (UR) and anteroposterior tilt.

Design

Psychometric analysis.

Methods

We recruited 57 participants—10 with and 47 without shoulder pain. Two physical therapists consecutively measured both scapular movements using the Clinometer app at the arm by the side (rest), 30°, 60°, 90°, and 120° of humeral elevation in the scapular plane; one therapist measured again after 2 days. For evaluating concurrent validity, we compared the Clinometer scores with those measured using an electromagnetic motion capture system in 10 healthy participants. Intraclass correlation coefficients (ICC) with standard error of measurement (SEM) and minimal detectable difference at 90% confidence intervals (MDD 90 ) were calculated. Concurrent validity was evaluated using repeated-measures analysis of variance followed by post hoc testing with Tukey–Kramer test ( P < .05).

Results

We observed good intrarater reliability (ICC: UR = .76–.85, tilt = .69–.9; SEM: 2.2°–3.5°; MDD 90 : ∼5°–8°) and moderate to good interrater reliability (ICC: UR = .66–.78, tilt = .66–.76; SEM: 3.6°–8°; MDD 90 : ∼9°–18°) for both rotations. The Clinometer scores for UR were comparable to electromagnetic motion capture system at all angles except 90° (difference ∼8°); for scapular tilt, the scores were comparable only at rest and 30° elevation.

Conclusion

The Clinometer app is reliable and valid for measuring scapular UR throughout and for scapular tilt at lower humeral elevation angles. The MDD 90 values for scapular rotations computed in this study can be helpful in rehabilitation planning and future research.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mobile ApplicationsShoulder JointHumansShoulder PainReproducibility of ResultsSmartphoneScapulaBiomechanical PhenomenaRange of Motion, Articular

Stichwörter der Autor:innen

biomechanicsmeasurement propertiespsychometricshoulder complex

Autor:innen und Institutionen

  • Indian Spinal Injuries Centre, Institute of Rehabilitation Sciences, New Delhi, India.
  • Department of Research, Indian Spinal Injuries Centre, New Delhi, India.

ORCID-Profile: Varmeet Kaur, Meena Makhija, Vandana Phadke

Zitieren

APA

Kaur, V., Makhija, M., & Phadke, V. (2023). Reliability and Concurrent Validity of Smartphone Clinometer Application for Measuring Scapular Rotations in Subjects With and Without Shoulder Pain. Journal of Sport Rehabilitation. https://doi.org/10.1123/jsr.2023-0005

Vancouver

Kaur V, Makhija M, Phadke V. Reliability and Concurrent Validity of Smartphone Clinometer Application for Measuring Scapular Rotations in Subjects With and Without Shoulder Pain. Journal of Sport Rehabilitation. 2023. doi:10.1123/jsr.2023-0005

BibTeX
@article{Kaur2023,
  author = {Kaur, Varmeet and Makhija, Meena and Phadke, Vandana},
  title = {Reliability and Concurrent Validity of Smartphone Clinometer Application for Measuring Scapular Rotations in Subjects With and Without Shoulder Pain},
  journal = {Journal of Sport Rehabilitation},
  year = {2023},
  doi = {10.1123/jsr.2023-0005}
}
Kostenlos starten →