Reliability and Concurrent Validity of Smartphone Clinometer Application for Measuring Scapular Rotations in Subjects With and Without Shoulder Pain
Journal of Sport Rehabilitation · 2023
DOI: 10.1123/jsr.2023-0005 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Sport Rehabilitation, 2023. Verfasst von Varmeet Kaur und 2 weiteren Autor:innen. Beteiligte Einrichtung: Indian Spinal Injuries Centre, Institute of Rehabilitation Sciences, New Delhi, India. Hauptthemen laut MEDLINE: Mobile Applications, Shoulder Joint. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben.
Abstract (Originalsprache)
Context
Clinical assessment of scapular motion is obscured by a lack of clinically accessible and feasible angular measurement tools. This study evaluates the reliability and validity of the smartphone “Clinometer” app in measuring scapular upward rotation (UR) and anteroposterior tilt.
Design
Psychometric analysis.
Methods
We recruited 57 participants—10 with and 47 without shoulder pain. Two physical therapists consecutively measured both scapular movements using the Clinometer app at the arm by the side (rest), 30°, 60°, 90°, and 120° of humeral elevation in the scapular plane; one therapist measured again after 2 days. For evaluating concurrent validity, we compared the Clinometer scores with those measured using an electromagnetic motion capture system in 10 healthy participants. Intraclass correlation coefficients (ICC) with standard error of measurement (SEM) and minimal detectable difference at 90% confidence intervals (MDD 90 ) were calculated. Concurrent validity was evaluated using repeated-measures analysis of variance followed by post hoc testing with Tukey–Kramer test ( P < .05).
Results
We observed good intrarater reliability (ICC: UR = .76–.85, tilt = .69–.9; SEM: 2.2°–3.5°; MDD 90 : ∼5°–8°) and moderate to good interrater reliability (ICC: UR = .66–.78, tilt = .66–.76; SEM: 3.6°–8°; MDD 90 : ∼9°–18°) for both rotations. The Clinometer scores for UR were comparable to electromagnetic motion capture system at all angles except 90° (difference ∼8°); for scapular tilt, the scores were comparable only at rest and 30° elevation.
Conclusion
The Clinometer app is reliable and valid for measuring scapular UR throughout and for scapular tilt at lower humeral elevation angles. The MDD 90 values for scapular rotations computed in this study can be helpful in rehabilitation planning and future research.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Indian Spinal Injuries Centre, Institute of Rehabilitation Sciences, New Delhi, India.
- Department of Research, Indian Spinal Injuries Centre, New Delhi, India.
ORCID-Profile: Varmeet Kaur, Meena Makhija, Vandana Phadke
Zitieren
APA
Kaur, V., Makhija, M., & Phadke, V. (2023). Reliability and Concurrent Validity of Smartphone Clinometer Application for Measuring Scapular Rotations in Subjects With and Without Shoulder Pain. Journal of Sport Rehabilitation. https://doi.org/10.1123/jsr.2023-0005
Vancouver
Kaur V, Makhija M, Phadke V. Reliability and Concurrent Validity of Smartphone Clinometer Application for Measuring Scapular Rotations in Subjects With and Without Shoulder Pain. Journal of Sport Rehabilitation. 2023. doi:10.1123/jsr.2023-0005
BibTeX
@article{Kaur2023,
author = {Kaur, Varmeet and Makhija, Meena and Phadke, Vandana},
title = {Reliability and Concurrent Validity of Smartphone Clinometer Application for Measuring Scapular Rotations in Subjects With and Without Shoulder Pain},
journal = {Journal of Sport Rehabilitation},
year = {2023},
doi = {10.1123/jsr.2023-0005}
}
EUVIMED