Liposome functionalized reduced graphene oxide for rapid electrochemical sensing of bacteria
Biointerphases · 2023
DOI: 10.1116/6.0002376 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biointerphases, 2023. Verfasst von Shailendra Kumar und 3 weiteren Autor:innen. Beteiligte Einrichtung: Nano-Cellular Medicine and Biophysics Laboratory, School of Biomedical Engineering, Indian Institute of Technology (Banaras Hindu University), Varana…. Hauptthemen laut MEDLINE: Graphite, Biosensing Techniques. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: Indian Council of Medical Research, University Grants Commission, Indian Institute of Technology.
Abstract (Originalsprache)
Pathogenic bacteria represent a severe threat to global public health, particularly with the growing rate of antibiotic resistance, and, therefore, indicate a critical need for developing efficient sensing platforms. Liposome-based sensors are collocating interest due to their intrinsic fusogenic ability to fuse with the outer membrane of bacteria. However, the lack of a conducting property limits their applicability for developing biosensing platforms. In this study, we report conjugation of liposomes with reduced graphene oxide (rGO) for fabricating a rapid and sensitive biosensor for electrochemical detection of Escherichia coli (E. coli). The large surface area of rGO facilitated binding of liposomes with their surface, and the intrinsic electrical and biocompatible properties assisted electrochemical sensing of bacteria. The electrochemical response of the liposome and the rGO-liposome coated electrode shows nonconducting and conducting characteristics, respectively. A significant change in the peak current of differential pulse voltammetry with the gradual variation of bacterial density in the electrolyte was observed for the glassy carbon electrode rGO-liposome (GCE-L-rGO) surface only. The detection sensitivity of GCE-L-rGO sensors was ∼26 μA/106 cells per ml of electrolyte for varying cell densities from 3 × 103 to 3 × 104 cells/ml. The proposed sensing technique can serve as an alternative to conventional methodologies for rapid and in situ detection of bacterial load in different samples, laying the foundation for new applications in clinical diagnostics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Nano-Cellular Medicine and Biophysics Laboratory, School of Biomedical Engineering, Indian Institute of Technology (Banaras Hindu University), Varanasi 221005, Uttar Pradesh, India.
- Department of Physics, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India.
ORCID-Profile: Shailendra Kumar, Juhi Jaiswal, Snehlata Yadav, Marshal Dhayal
Förderung
- Indian Council of Medical Research
- University Grants Commission
- Indian Institute of Technology
Zitieren
APA
Kumar, S., Jaiswal, J., Yadav, S., & Dhayal, M. (2023). Liposome functionalized reduced graphene oxide for rapid electrochemical sensing of bacteria. Biointerphases. https://doi.org/10.1116/6.0002376
Vancouver
Kumar S, Jaiswal J, Yadav S, Dhayal M. Liposome functionalized reduced graphene oxide for rapid electrochemical sensing of bacteria. Biointerphases. 2023. doi:10.1116/6.0002376
BibTeX
@article{Kumar2023,
author = {Kumar, Shailendra and Jaiswal, Juhi and Yadav, Snehlata and Dhayal, Marshal},
title = {Liposome functionalized reduced graphene oxide for rapid electrochemical sensing of bacteria},
journal = {Biointerphases},
year = {2023},
doi = {10.1116/6.0002376}
}
EUVIMED