Fachartikel in der Zeitschrift Molecules, 2023. Verfasst von Ruixiang Liu und 1 weiteren Autor:innen. Beteiligte Einrichtung: College of Physical Education, Shanxi University, Taiyuan 030006, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Graphite, beta-Cyclodextrins. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The monitoring of potassium ion (K+) levels in human sweat can provide valuable insights into electrolyte balance and muscle fatigue non-invasively. However, existing laboratory techniques for sweat testing are complex, while wearable sensors face limitations like drift, fouling and interference from ions such as Na+. This work develops printed electrodes using β-cyclodextrin functionalized reduced graphene oxide (β-CD-RGO) for selective K+ quantification in sweat. The β-CD prevents the aggregation of RGO sheets while also providing selective binding sites for K+ capture. Electrodes were fabricated by screen printing the β-CD-RGO ink onto conductive carbon substrates. Material characterization confirmed the successful functionalization of RGO with β-CD. Cyclic voltammetry (CV) showed enhanced electrochemical behavior for β-CD-RGO-printed electrodes compared with bare carbon and RGO. Sensor optimization resulted in a formulation with 30% β-CD-RGO loading. The printed electrodes were drop-casted with an ion-selective polyvinyl chloride (PVC) membrane. A linear range from 10 μM to 100 mM was obtained along with a sensitivity of 54.7 mV/decade. The sensor showed good reproducibility over 10 cycles in 10 mM KCl. Minimal interference from 100 mM Na+ and other common sweat constituents validated the sensor’s selectivity. On-body trials were performed by mounting the printed electrodes on human subjects during exercise. The K+ levels measured in sweat were found to correlate well with serum analysis, demonstrating the sensor’s ability for non-invasive electrolyte monitoring. Overall, the facile synthesis of stable β-CD-RGO inks enables the scalable fabrication of wearable sensors for sweat potassium detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesGraphitebeta-CyclodextrinsHumansSweatPotassiumReproducibility of ResultsCarbonElectrodesElectrochemical Techniques

Stichwörter der Autor:innen

ion-selective electrodepotassiumreduced graphene oxidescreen printingsweat monitoringwearable sensor

Substanzen

graphene oxidePotassiumGraphiteCarbonbeta-Cyclodextrins

Autor:innen und Institutionen

  • College of Physical Education, Shanxi University, Taiyuan 030006, China.

Zitieren

APA

Liu, R., & Shi, X. (2023). Preparation of β-Cyclodextrin Functionalized Platform for Monitoring Changes in Potassium Content in Perspiration. Molecules. https://doi.org/10.3390/molecules28197000

Vancouver

Liu R, Shi X. Preparation of β-Cyclodextrin Functionalized Platform for Monitoring Changes in Potassium Content in Perspiration. Molecules. 2023. doi:10.3390/molecules28197000

BibTeX
@article{Liu2023,
  author = {Liu, Ruixiang and Shi, Xiaofeng},
  title = {Preparation of β-Cyclodextrin Functionalized Platform for Monitoring Changes in Potassium Content in Perspiration},
  journal = {Molecules},
  year = {2023},
  doi = {10.3390/molecules28197000}
}
Kostenlos starten →